CLI Guide

Displays a single object from a particular group.
racadm getconfig -g cfgSerial -o cfgSerialBaudRate
Displays an indexed group.
racadm getconfig -g cfgUserAdmin -o cfgUserAdminUserName -i 2
Displays the current Enhanced Cooling Mode property conguration.
racadm getconfig –g cfgThermal
getdcinfo
Table 28. Details of getdcinfo attribute
Description Displays general I/O module and daughter card conguration information. Only the CMC controls daughter cards.
To run this subcommand, you must have the CMC Login User privilege.
NOTE: Fabric verication for server DCs is performed only when the chassis is turned on. When the
chassis is on standby power, iDRACs on the server modules remain turned o and thus are unable to
report the server's DC fabric type. The DC fabric type may not be reported in the CMC user interface
until iDRAC on the server is turned on.
Synopsis
racadm getdcinfo
racadm getdcinfo [-n]
Input -n — Displays the model names for the daughter cards in servers.
Table 29. Example 1
<IO#> <Type> <State> <Role>
switch-1 Gigabit Ethernet OK Master
switch-2 None N/A N/A
switch-3 Gigabit Ethernet OK Master
switch-4 None N/A N/A
switch-5 Gigabit Ethernet OK Member
switch-6 None N/A N/A
Table 30. Example 2
<Server#> <Presence> <DC1 Type> <DC1 State> <DC2 Type> <DC2 State>
server-1 Present None N/A None N/A
server-2 Not Present None N/A None N/A
server-3 Not Present None N/A None N/A
server-4 Present None N/A Gigabit
Ethernet
OK
server-5 Not Present None N/A None N/A
38 RACADM Subcommand Details