CLI Guide
Module ID = 1
Severity = Critical
Message = The storage battery has failed.
Module ID = 10
Severity = Critical
Message = General failure after video.
Module ID = ps-6
Severity = Critical
Message = The power input for power supply 6 is lost.
• To display the Critical error messages for all the components.
racadm getactiveerrors –s critical
Module ID = 1
Severity = Critical
Message = The storage battery has failed.
Module ID = 10
Severity = Critical
Message = General failure after video.
Module ID = ps-6
Severity = Critical
Message = The power input for power supply 6 is lost.
• To display critical error messages for server–1.
racadm getactiveerrors –s critical –m server-1
Module ID = 1
Severity = Critical
Message = The storage battery has failed.
• The error message displayed for invalid syntax.
racadm getactiveerrors –z cmc-1
ERROR: The syntax of the command specified is not correct.
• The error message displayed for invalid parameter.
racadm getactiveerrors –m server-80
ERROR: The syntax of the command specified is not correct.
• To display entire information log.
racadm getactiveerrors -s info
Module ID = 1
Severity = Critical
Message = A fabric mismatch deteceted for mezzanine card B1.
Module ID = ps-1
Severity = Critical
Message = The power input for power supply 1 is lost.
Module ID = ps-3
Severity = Critical
Message = The power input for power supply 3 is lost.
Module ID = cmc-1
Severity = NonCritical
Message = A firmware or software incompatibilty detected between system BIOS
in slot 4 and CMC.
• Display specic module log:
racadm getactiveerrors -m server-1
34
RACADM Subcommand Details