CLI Guide

Default
0
cfgThermal
This group displays and congures the thermal settings. Use this object with the cong or getcong subcommands.
To set the congurations, you must have the Chassis Conguration Administrator privileges.
cfgThermalMFSPercent (Read or Write)
Table 324. Details of cfgThermalMFSPercent attribute
Description
Congures the minimum fan speed in percent.
Legal Values
0 to 100
Default
0
cfgThermalEnhancedCoolingMode (Read or Write)
Table 325. Details of cfgThermalEnhancedCoolingMode attribute
Description
Congures the enhanced cooling mode.
Legal Values
1 — Enabled
0 — Disabled
Default 0 — Disabled
cfgKVMInfo
This group is used to display information for and congure the iKVM.
Use this object with the cong or getcong subcommands.
To use this object property, you must have Chassis Conguration Administrator privilege.
cfgKVMAccessToCMCEnable (Read or Write)
Table 326. Details of cfgKVMAccessToCMCEnable attribute
Description
Enables or disables the Dell CMC Console access on the iKVM.
Legal Values
1 (Enable)
0 (Disable)
158 CMC Property Database Group and Object Descriptions