CLI Guide

cfgSsnMgtSshIdleTimeout (Read or Write)
Table 184. Details of cfgSsnMgtSshIdleTimeout attribute
Description
Denes the secure shell idle time-out. This property sets the amount of time (in seconds) that a connection is
allowed to remain idle (there is no user input). The session is canceled if the time limit exceeds this property.
Changes to this setting do not aect the current session; log out and log in again to make the new settings eective.
After the message is displayed, the system returns to the shell that generated the Secure Shell session.
Legal Values
0 —(No timeout)
60–10800
NOTE: If 0 (no timeout), the network connection does not send alive packets to probe the client.
Otherwise, keep alive packets are sent to guarantee that the client is responding.
Default
1800
cfgSsnMgtTelnetIdleTimeout - Read or Write
Table 185. Details of cfgSsnMgtTelnetIdleTimeout attribute
Description
Denes the Telnet idle timeout. This property sets the amount of time in seconds that a connection is allowed to
remain idle (there is no user input). The session is canceled if the time limit exceeds this property. Changes to this
setting do not aect the current session (you must log out and log in again to make the new settings eective.)
After the message is displayed, the system returns you to the shell that generated the Telnet session.
0 (No timeout)
60–10800
NOTE: If 0 (no timeout is specied), the network connection does not send alive packets to probe the
client. Otherwise, keep alive packets are sent to guarantee that the client is responding.
Default
1800
cfgSerial
This group contains conguration parameters for the serial conguration. One instance of the group is allowed.
Use this object with the cong or getcong subcommands.
To use this object property, you must have the Chassis Conguration Administrator privilege.
The following sections provide information about the objects in the cfgSerial group.
114
CMC Property Database Group and Object Descriptions