The valid values for <VLAN id> are 1 4000 and 4021 4094. Default is 1.
For example:
racadm config -g cfgLanNetworking -o cfgNicVlanID
1
3. Then, specify the VLAN priority for the external chassis management network:
racadm config -g cfgLanNetworking -o
cfgNicVLanPriority <VLAN priority>
The valid values for <VLAN priority> are 07. Default is 0.
For example:
racadm config -g cfgLanNetworking -o
cfgNicVLanPriority 7
You can also specify both the VLAN ID and the VLAN priority with a single command:
racadm setniccfg -v <VLAN id> <VLAN priority>
For example:
racadm setniccfg -v 1 7
4. To remove the CMC VLAN, disable the VLAN capabilities of the external chassis management network:
racadm config -g cfgLanNetworking -o
cfgNicVLanEnable 0
You can also remove the CMC VLAN using the following command:
racadm setniccfg -v
Federal Information Processing Standards
The agencies and contractors of the Federal government of the United States use Federal Information Processing Standards
(FIPS), a computer security standard, which is related to all applications that have communicative interfaces. The 1402
comprises of four levels Level 1, Level 2, Level 3, and Level 4. The FIPS 1402 series stipulate that all communicative
interfaces must have the following security properties:
authentication
confidentiality
message integrity
non-repudiation
availability
access control
If any of the properties depend on cryptographic algorithms, then FIPS must approve these algorithms.
By default, the FIPS mode is disabled. When FIPS is enabled, the minimum key size for OpenSSL FIPS is SSH-2 RSA 2048 bits.
NOTE: PSU firmware update is not supported when the FIPS mode is enabled in the chassis.
For more information, see CMC Online Help.
The following features/applications support FIPS.
Web GUI
RACADM
WSMan
SSH v2
SMTP