LCD Module and Server Status Information
The tables in this section describe status items that are displayed on the front panel LCD for each type of component in the
chassis.
Table 64. CMC Status
Item Description
Example: CMC1, CMC2 Name or Location.
No Errors If there are no errors then the message No Errors is displayed, else error messages are listed.
Critical errors are listed first, followed by warnings.
Firmware Version Only displays on an active CMC. Displays Standby for the standby CMC.
IP4 <enabled, disabled> Displays current IPv4 enabled state only on an active CMC.
IP4 Address: <address,
acquiring>
Only displays if IPv4 is enabled only on an active CMC.
IP6 <enabled, disabled> Displays current IPv6 enabled state only on an active CMC.
IP6 Local Address:
<address>
Only displays if IPv6 is enabled only on an active CMC.
IP6 Global Address:
<address>
Only displays if IPv6 is enabled only on an active CMC.
MAC: <address> Displays the CMC's MAC address.
Table 65. Chassis or Enclosure Status
Item Description
User Define
Name
Example: Dell Rack System. You can set this option through the CMC Command Line Interface (CLI) or
Web interface.
Error Messages If there are no errors then the message No Errors is displayed, else error messages are listed. Critical
errors are listed first, followed by warnings.
Model Number Example "PowerEdgeM1000e".
Power
Consumption
Current power consumption in watts.
Peak Power Peak power consumed in watts.
Minimum Power Minimum power consumed in watts.
Ambient
Temperature
Current ambient temperature in degrees Celsius.
Service Tag The factory-assigned service tag.
CMC redundancy
mode
Non-Redundant or Redundant.
PSU redundancy
mode
Non-Redundant, AC Redundant, or DC Redundant.
Table 66. Fan Status
Item Description
Name/Location Example: Fan1, Fan2, and so on.
238 Using LCD Panel Interface