Users Guide

Table Of Contents
To enable the power remote logging feature, type the following command:
racadm config -g cfgRemoteHosts -o cfgRhostsSyslogPowerLoggingEnabled 1
To specify the desired logging interval, type the following command:
racadm config -g cfgRemoteHosts -o cfgRhostsSyslogPowerLoggingInterval n
where n is 1-1440 minutes.
To determine if the power remote logging feature is enabled, type the following command:
racadm getconfig -g cfgRemoteHosts -o cfgRhostsSyslogPowerLoggingEnabled
To determine the power remote logging interval, type the following command:
racadm getconfig -g cfgRemoteHosts -o cfgRhostsSyslogPowerLoggingInterval
The power remote logging feature is dependent on remote syslog hosts having been previously configured. Logging
to one or more remote syslog hosts must be enabled, otherwise power consumption is logged. This can be done
either through the Web interface or the RACADM CLI. For more information, see the remote syslog configuration
instructions in the Chassis Management Controller for Dell PowerEdge M1000e RACADM Command Line Reference
Guide at dell.com/support/manuals.
To enable remote power management using the Dell OpenManage Power Center, type:
racadm config -g cfgChassisPower -o cfgChassisServerBasedPowerMgmtMode 1
To restore CMC power management, type:
racadm config -g cfgChassisPower -o cfgChassisServerBasedPowerMgmtMode 0
For information about RACADM commands for chassis power, see the config, getconfig, getpbinfo, and
cfgChassisPower sections in the Chassis Management Controller for Dell PowerEdge M1000e RACADM Command Line
Reference Guide.
Executing Power Control Operations
You can execute the following power control operation for the chassis, servers, and IOMs.
NOTE: Power control operations affect the entire chassis.
Related concepts
Executing Power Control Operations on the Chassis on page 213
Executing Power Control Operations on a Server on page 214
Executing Power Control Operations on an IOM on page 215
Executing Power Control Operations on the Chassis
CMC enables you to remotely perform several power management actions, such as an orderly shutdown, on the entire chassis
(chassis, servers, IOMs, iKVM, and PSUs).
NOTE: To perform power management actions, you must have Chassis Configuration Administrator privilege.
Executing Power Control Operations on the Chassis Using Web Interface
To execute power control operations on the chassis using the CMC Web interface:
1. In the system tree, go to Chassis Overview and click Power > Control.
The Chassis Power Control page is displayed.
2. Select one of the following power control operations:
Managing and Monitoring Power
213