Users Guide

Table Of Contents
NOTE: Do not configure I/O module network settings for Ethernet pass-through and Infiniband switches.
Configuring Network Settings for IOMs Using CMC Web Interface
NOTE: This feature is supported on PowerEdge M I/O Aggregator IOM only. Other IOMs including MXL 10/40GbE are not
supported.
To configure the network settings for IOM(s) using the CMC web interface:
1. In the system tree, go to I/O Module Overview and click Setup or expand I/O Module Overview, select the IOM, and
click Setup.
The Deploy I/O Modules page displays the IOMs that are powered on.
2. For the required IOMs, enable DHCP, enter the IP address, subnet mask, and gateway address.
3. For IOMs that are manageable, enter root password, SNMP RO Community string, and Syslog Server IP Address. For
information about the fields, see CMC Online Help.
NOTE: The IP address set on the IOMs from CMC is not saved to the switch's permanent startup configuration.
To save the IP address configuration permanently, you must enter the connect switch-n command, or racadm
connect switch -n RACADM command, or use a direct interface to the IOM GUI to save this address to the startup
configuration file.
NOTE: The SNMP community string can have any printable character whose ASCII value is the range, 33125.
4. Click Apply.
The network settings are configured for the IOM(s).
NOTE:
For IOMs that are manageable, you can reset the VLANs, network properties, and IO ports to default
configurations.
Configuring Network Settings for IOMs Using RACADM
To configure the network settings for IOMs using RACADM, set the date and time. See the deploy command section in the
Chassis Management Controller for Dell PowerEdge M1000e RACADM Command Line Reference Guide.
You can set the username, password, and SNMP string for an IOM using the RACADM deploy command:
racadm deploy -m switch-<n> -u root -p <password>
racadm deploy -m switch-<n> -v SNMPv2 <snmpCommunityString> ro
racadm deploy -a [server|switch] -u root -p <password>
Resetting IOM to Factory Default Settings
You can reset IOM to the factory default settings using the Deploy I/O Modules page.
NOTE:
This feature is supported on PowerEdge M I/O Aggregator IOM only. Other IOMs including MXL 10/40GbE are not
supported.
To reset the selected IOMs to factory default settings using the CMC Web interface:
1. In the system tree, go to I/O Module Overview and click Setup or expand I/O Module Overview in the system tree,
select the IOM, and click Setup.
The Deploy I/O Modules page displays the IOM(s) that are powered on.
2. For the required IOM(s), click Reset.
A warning message is displayed.
3. Click OK to continue.
178
Managing Input Output Fabric