Users Guide
The following gure shows the QuickDeploy IP addresses assignment to the servers when there are 16 half height severs in a
M1000e chassis:
The following gure shows the QuickDeploy IP addresses assignment to the servers when there are 32 quarter height severs in a
M1000e chassis:
Conguring Reserved QuickDeploy IP Addresses Using RACADM
To modify the number of static IP addresses allocated for servers on the chassis using RACADM, use the following command:
racadm deploy –q -n <num>
where <num> is the number of IP addresses, 8. 16, or 32.
To view current settings for the number of reserved IP addresses and the Use CMC DNS Settings for servers on the chassis using
RACADM, use the following command:
racadm deploy –q
To modify the Use the CMC DNS Settings option to enable quick deploy for servers on the chassis using RACADM, use the
following command:
racadm deploy -q -e <enable/disable>
For more information, see the Chassis Management Controller for Dell PowerEdge M1000e RACADM Command Line Reference
Guide available at dell.com/support/manuals.
Modifying iDRAC Network Settings for Individual Server iDRAC
Using this table you can congure the iDRAC network congurations settings for each installed server. The initial values displayed for
each of the elds are the current values read from the iDRAC.
To modify the iDRAC Network Settings using the CMC Web interface:
1. In the system tree, go to Server Overview, and then click Setup → iDRAC. The Deploy iDRAC page is displayed. The iDRAC
Network Settings section lists all installed server’s iDRAC IPv4 and IPv6 network conguration settings.
2. Modify the iDRAC network settings as required for the servers.
NOTE: You must select the Enable LAN option to specify the IPv4 or IPv6 settings. For information about the elds,
see CMC Online Help.
3. To deploy the setting to iDRAC, click Apply iDRAC Network Settings. If you made changes to the QuickDeploy settings, they
are also saved.
The iDRAC Network Settings table reects future network conguration settings; the values shown for installed servers may
or may not be the same as the currently installed iDRAC network conguration settings. Click Refresh to update the iDRAC
Deploy page with each installed iDRAC network conguration settings after changes are made.
NOTE: Changes made to QuickDeploy elds are immediate, but changes made to one or more iDRAC server network
conguration settings may require a couple of minutes to propagate from CMC to iDRAC. Clicking Refresh too soon
may display only partially correct data for a one or more iDRAC servers.
Modifying iDRAC Network Settings Using RACADM
RACADM config or getconfig commands support the -m <module> option for the following conguration groups:
99