WWN or MAC Addresses
The WWN/MAC Address section displays the WWN/MAC information that is assigned to all servers, even if those server slots are
currently empty.
Location displays the location of the slot occupied by the Input/Output modules. The six slots are identied by a combination of
the group name (A, B, or C) and slot number (1 or 2): slot names A1, A2, B1, B2, C1, or C2. iDRAC is the server's integrated
management controller.
Fabric displays the type of the I/O fabric.
Server-Assigned displays the server-assigned WWN/MAC addresses embedded in the controller's hardware.
Chassis-Assigned displays the chassis-assigned WWN/MAC addresses used for the particular slot.
A green check mark in the Server-Assigned or in Chassis-Assigned columns indicates the type of active addresses. Chassis-
assigned addresses are assigned when FlexAddress is activated on the chassis, and represents the slot-persistent addresses. When
ChassisaAssigned addresses are checked, those addresses are used even if one server is replaced with another server.
Command Messages
The following table lists the RACADM commands and output for common FlexAddress situations.
Table 38. FlexAddress Commands and Output
Situation Command Output
SD card in the active CMC module is
bound to another service tag.
$racadm featurecard -s
The feature card inserted is
valid and contains the
following feature(s)
FlexAddress: The feature card
is bound to another chassis,
svctag = <Service tag Number>
SD card SN = <Valid flex
address serial number>
SD card in the active CMC module that
is bound to the same service tag.
$racadm featurecard -s
The feature card inserted is
valid and contains the
following feature(s)
FlexAddress: The feature card
is bound to this chassis
SD card in the active CMC module that
is not bound to any service tag.
$racadm featurecard -s
The feature card inserted is
valid and contains the
following feature(s)
FlexAddress: The feature card
is not bound to any chassis
FlexAddress feature not active on the
chassis for any reason (No SD card
inserted/ corrupt SD card/ after feature
deactivated /SD card bound to a
dierent chassis).
$racadm setflexaddr [-f
<fabricName> <slotState>]
$racadm setflexaddr [-i
<slot#> <slotstate>]
ERROR: Flexaddress feature is
not active on the chassis
Guest user attempts to set FlexAddress
on slots or fabrics.
$racadm setflexaddr [-f
<fabricName> <slotState>]
$racadm setflexaddr [-i
<slot#> <slotstate>]
ERROR: Insufficient user
privileges to perform
operation
Deactivating FlexAddress feature with
chassis powered ON.
$racadm feature -d -c
flexaddress
ERROR: Unable to deactivate
the feature because the
chassis is powered ON
Guest user tries to deactivate the
feature on the chassis.
$racadm feature -d -c
flexaddress
ERROR: Insufficient user
privileges to perform
operation
163