Users Guide

Viewing WWN or MAC Address Information Using RACADM
To view WWN/MAC address information for all servers or specic servers using RACADM, use the getexaddr and getmacaddress
subcommands.
To display Flexaddress for the entire chassis, use the following RACADM command:
racadm getflexaddr
To display Flexaddress status for a particular slot, use the following RACADM command:
racadm getflexaddr [-i <slot#>]
where <slot #> is a value from 1 to 16.
To display the NDC or LOM MAC address, use the following RACADM command:
racadm getmacaddress
To display the MAC address for chassis, use the following RACADM command:
racadm getmacaddress -m chassis
To display the iSCSI MAC addresses for all servers, use the following RACADM command:
racadm getmacaddress -t iscsi
To display the iSCSI MAC for a specic server, use the following RACADM command:
racadm getmacaddress [-m <module> [-x]] [-t iscsi]
To display the user-dened MAC and WWN address, use the following RACADM command:
racadm getmacaddress -c io-identity
racadm getmacaddress -c io-identity -m server -2
To display the console assigned MAC/WWN of all LOMs or mezzanine cards, use the following RACADM command:
racadm getmacaddress -c all
To display the chassis assigned WWN/MAC address, use the following RACADM command:
racadm getmacaddress -c flexaddress
To display the MAC/WWN addresses for all LOMs or mezzanine cards, use the following RACADM command:
racadm getmacaddress -c factory
To display the Ethernet and iSCSI MAC/WWN addresses for all iDRAC/LOMs/mezzanine cards, use the following RACADM
command:
racadm getmacaddress -a
For more information on the getexaddr and getmacaddress subcommand, see the Chassis Management Controller for PowerEdge
M1000e RACADM Command Line Reference Guide.
Viewing World Wide Name or Media Access Control IDs
The WWN/MAC Summary page allows you to view the World Wide Name (WWN) conguration and Media Access Control (MAC)
address of a slot in the chassis.
Fabric Conguration
The Fabric Conguration section displays the type of Input/Output fabric that is installed for Fabric A, Fabric B, and Fabric C. A
green check mark indicates that the fabric is enabled for FlexAddress. The FlexAddress feature is used to deploy chassis assigned
and slot persistent WWN/MAC addresses to various fabrics and slots within the chassis. This feature is enabled on a per fabric and
per slot basis.
NOTE: For more information on the FlexAddress feature, see About Flexaddress.
162