Users Guide

The command returns the following status message if it is successfully deactivated:
feature FlexAddress is deactivated on the chassis successfully.
If the chassis is not powered-down prior to execution, the command fails with the following error message:
ERROR: Unable to deactivate the feature because the chassis is powered ON
For further information on the command, see the feature command section of the Chassis Management Controller for Dell
PowerEdge M1000e RACADM Command Line Reference Guide.
Conguring FlexAddress
FlexAddress is an optional upgrade that allows server modules to replace the factory-assigned WWN/MAC ID with a WWN/MAC ID
provided by the chassis.
NOTE: In this section, the term FlexAddress also indicates FlexAddress Plus.
Purchase and install the FlexAddress upgrade to congure the FlexAddress. If the upgrade is not purchased and installed, the
following text is displayed on the Web interface:
Optional feature not installed. See the Dell Chassis Management Controller Users Guide for
information on the chassis-based WWN and MAC address administration feature. To purchase
this feature, please contact Dell at www.dell.com.
If you purchase FlexAddress with your chassis, it is installed and active when you power up your system. If you purchase FlexAddress
separately, you must install the SD feature card using the instructions in the Chassis Management Controller (CMC) Secure Digital
(SD) Card Technical Specication document at dell.com/support/manuals.
The server must be turned o before you begin conguration. You can enable or disable FlexAddress on a per fabric basis.
Additionally, you can enable or disable the feature on a per slot basis. After you enable the feature on a per-fabric basis, you can then
select slots to be enabled. For example, if Fabric-A is enabled, any slots that are enabled have FlexAddress enabled only on Fabric- A.
All other fabrics use the factory-assigned WWN/MAC on the server.
Selected slots have FlexAddress enabled for all fabrics that are enabled. For example, it is not possible to enable Fabric-A and B, and
have Slot 1 be FlexAddress enabled on Fabric-A but not on Fabric-B.
NOTE: Make sure that the Blade Servers are powered o before changing the fabric level (A, B, C, or DRAC) ex
address.
Related link
Wake-On-LAN with FlexAddress
Conguring FlexAddress for Chassis-Level Fabric and Slots
Conguring FlexAddress for Server-Level Slots
Additional FlexAddress Conguration for Linux
Wake-On-LAN with FlexAddress
When the FlexAddress feature is deployed for the rst time on a given server module, it requires a power-down and power-up
sequence for FlexAddress to take eect. FlexAddress on Ethernet devices is programmed by the server module BIOS. For the server
module BIOS to program the address, it needs to be operational which requires the server module to be powered up. When the
power-down and power-up sequences complete, the chassis-assigned MAC IDs are available for Wake-On-LAN (WOL) function.
Conguring FlexAddress for Chassis-Level Fabric and Slots
At the chassis level, you can enable or disable the FlexAddress feature for fabrics and slots. FlexAddress is enabled on a per-fabric
basis and then slots are selected for participation in the feature. Both fabrics and slots must be enabled to successfully congure
FlexAddress.
Conguring FlexAddress for Chassis-Level Fabric and Slots Using CMC Web Interface
To enable or disable fabrics and slots to use the FlexAddress feature using the CMC Web interface:
1. In the system tree, go to Server Overview, and then click Setup FlexAddress.
158