CLI Guide
One instance of the group is allowed. Some objects in this group may require CMC NIC to be reset, which may cause a brief loss in
connectivity. Objects that change CMC NIC IP address settings close all active user sessions and require users to reconnect using the
updated IP address settings.
Use this object with the cong or getcong subcommands.
To use this object property, you must have the Chassis Conguration Administrator privilege.
NOTE: You can congure a setting that does not have a hash sign (#) prexed in the output. To modify a congurable object, use
the —o option.
The following sections provide information about the objects in the cfgLanNetworking group.
cfgNicIPv4Enable (Read or Write)
Description
Enables or disables IPv4 stack.
Legal Values
• 1 (TRUE)
• 0 (FALSE)
Default
0
cfgNicVLanEnable (Read or Write)
Description
Enables or disables the VLAN capabilities.
All chassis management trac, including the CMC and all iDRACs, resides on this external VLAN when enabled. No
iDRAC conguration change is required to use this external management network VLAN.
Legal Values
• 1 (TRUE)
• 0 (FALSE)
Default
0
Example
racadm config -g cfgLanNetworking -o cfgNicVLanEnable
1
racadm config -g cfgLanNetworking -o cfgNicVLanEnable
0
cfgNicVLanID (Read or Write)
Description
Species the VLAN ID for the network VLAN conguration. This property is only valid if cfgNicVLanEnable is set
to 1(enabled).
Legal Values
1–4000 and 4021–4094
Default
1
Example
racadm config -g cfgLanNetworking -o cfgNicVlanID
1