CLI Guide

One instance of the group is allowed. Some objects in this group may require CMC NIC to be reset, which may cause a brief loss in
connectivity. Objects that change CMC NIC IP address settings close all active user sessions and require users to reconnect using the
updated IP address settings.
Use this object with the cong or getcong subcommands.
To use this object property, you must have the Chassis Conguration Administrator privilege.
NOTE: You can congure a setting that does not have a hash sign (#) prexed in the output. To modify a congurable object, use
the —o option.
The following sections provide information about the objects in the cfgLanNetworking group.
cfgNicIPv4Enable (Read or Write)
Description
Enables or disables IPv4 stack.
Legal Values
1 (TRUE)
0 (FALSE)
Default
0
cfgNicVLanEnable (Read or Write)
Description
Enables or disables the VLAN capabilities.
All chassis management trac, including the CMC and all iDRACs, resides on this external VLAN when enabled. No
iDRAC conguration change is required to use this external management network VLAN.
Legal Values
1 (TRUE)
0 (FALSE)
Default
0
Example
racadm config -g cfgLanNetworking -o cfgNicVLanEnable
1
racadm config -g cfgLanNetworking -o cfgNicVLanEnable
0
cfgNicVLanID (Read or Write)
Description
Species the VLAN ID for the network VLAN conguration. This property is only valid if cfgNicVLanEnable is set
to 1(enabled).
Legal Values
1–4000 and 4021–4094
Default
1
Example
racadm config -g cfgLanNetworking -o cfgNicVlanID
1
CMC Property Database Group and Object Descriptions 89