CLI Guide
setniccfg
Description Sets the CMC IP address for static and DHCP modes.
To run this subcommand, you must have the Congure Chassis Administrator privilege.
NOTE: The command helps to modify network conguration properties.
NOTE: The terms NIC and Ethernet management port may be used interchangeably.
Synopsis
• racadm setniccfg [-m <module>] -d [-6]
• racadm setniccfg [-m <module>] -s <ipAddress> <netmask> <gateway>
• racadm setniccfg [-m <module>] -s -6 <ipv6Address> <prefixlen> <gateway>
• racadm setniccfg [-m <module>] -v [<vlan_id> <vlan_priority>]
• racadm setniccfg [-m chassis] -o
• racadm setniccfg –p [-6]
• racadm setniccfg [-m <module>] -k [<speed> <duplex>]
• racadm setniccfg [-i <slot>] -v [<vlan_id> <vlan_priority>]
Input
• -d — Enables DHCP for the NIC. It is enabled by default.
• -d6 — Enables AutoCong for the NIC (default is disabled).
• -s — Enables static IP settings. The IPv4 address, netmask, and gateway must be specied. Otherwise, the
existing static settings are used. <ipaddress>, <netmask>, and <gateway> must be typed as dot-
separated strings.
racadm setniccfg -s 192.168.0 255.255.255.0 192.168.0
•
-s6 — Enables static IPv6 settings. The IPv6 address, Prex Length, and the IPv6 Gateway can be specied.
• -o — Enable or disable NIC.
• -m<module> — Must be one of the following values:
• chassis — Default state if -m is not specied
• server–<n>: where n=1–16
• server–<nx>: where n=1–8; x=a–d (lower case)
• switch–<n>: where n=1–6
• -v — VLAN settings has following legal values: no arguments imply remove VLAN tag, not compatible with
server–nx (for example "server–4b") notation <vlan_id>=between 1 and 4000, 4021 and 4094, inclusive
<vlan_priority>=between 0 and 7, inclusive.
• -p — Disables IPv4(default) or IPv6 protocol.
• -k — Option has following legal values: no arguments imply autonegotiate <speed>=10, 100 <duplex> =half,
full.
NOTE:
• -o, -k, -p: These options can be specied for chassis only
• -6: Sets static IPv6 addresses (with -soption). Enables autocong for IPv6 (with-d option) disables IPv6
(with
-p option) can be specied for chassis or servers.
• -v: When performing on a switch, release and renew any DHCP lease on that port for changes to take
eect.
Example
• Conguration of Speed= 100 Mbps and duplex= full duplex.
racadm setniccfg -k 100 full
• Conguration of Speed and Duplex to Autonegotiate.
racadm setniccfg -k
• Conguration of VLAN id and priority of a slot or all blades in a sleeve.
racadm setniccfg -i 5 -v 1000 7
RACADM Subcommand Details 75