CLI Guide

racadm setflexaddr -f <fabricName> 0|1
Input
-i <slotNum> — Enables or disables FlexAddress for the specied slot.
-f <fabricName> — Enables or disables FlexAddress for the specied fabric.
<slotNum>= 1–16
<fabricName>= A, B, C, iDRAC
0 : Disable
1 : Enable
Example
Disable exaddress for slot 2.
racadm setflexaddr -i 2 0
Enable exaddress for fabric A.
racadm setflexaddr -f A 1
Disable exaddress for fabric B.
racadm setflexaddr -f b 0
Disable exaddress for fabric iDRAC.
racadm setflexaddr -f idrac 0
setled
Description
Sets the state (blinking or not blinking) of the LED on the specied module.
To blink or unblink the chassis, I/O modules or the CMC, you must have the Debug Administrator privilege. To enable
the servers to blink or unblink, you must have the Server Administrator or the Debug Administrator privilege.
Synopsis
racadm setled -m <module> -l <ledState>
Input
-m <module>Species the module whose LED you want to congure.
<module> can be one of the following:
server–<n>, where n=1–16
server–<nx>, where n=1–8; x = a, b, c, d (lower case)
switch–<n>, where n=1–6
cmc-active
chassis
-l <ledState>Species the LED state. The values are:
0 — No Blinking
1 — Blinking
Example
racadm setled -m chassis -l 1
Sets LED state on Chassis to Blink
racadm setled -m server-1 -1 1
LED state was set successfully.
racadm setled -m server-9 -1 1
ERROR: Server in slot 9 is an extension of the server in slot 1.
NOTE: The setled command generates an error when run on the extension slot of a multi-slot
server.
74 RACADM Subcommand Details