CLI Guide
Server-2 Not Installed Not Present Not Installed Not Installed Not Installed
Server-3-A Reserved Present
Switch-4 Not Installed Not Present Not Installed Not Installed Not Installed
Switch-1 Not Installed Not Present Not Installed N/A N/A
NOTE: If the I/O Modules in slots 1 and 2 are absent and the getmacaddress -a and getmacaddress —c all commands
are run, the output is displayed as Not Installed in the following columns:
• <Presence>
• <NIC1 MAC Address>
• <NIC2 MAC Address>
getmodinfo
Description Displays conguration and status information for all modules or a specied module (server, switch, CMC, fan unit,
power supply unit (PSU), KVM, or I2C cable) in the chassis.
A power state of "Primary" denotes Active CMC.
To run this subcommand, you must have the CMC Login User privilege.
NOTE: The Service tag eld is blank for modules that do not have service tag.
Synopsis
racadm getmodinfo [-m <module>] [-A]
Input
• -m <module> — Species the module whose conguration and status information you want to view. The
default command (no options) displays information about all major components in the chassis.
<module> may be any of the following values:
• server-<n> where n=1–16
• server-<nx> where n=1–8; x = a, b, c, d
• switch-<n> where n=1–6
• cmc-<n> where n=1–2
• fan-<n> where n=1–9
• ps-<n> where n=1–6
• chassis
• kvm
• io-cable
• fpc-cable
• -A — Suppresses headers or labels in the output.
Examples
Display status of all the modules in the chassis
racadm getmodinfo
Display status of fan module 3 in the chassis
racadm getmodinfo -m fan-3
• racadm getmodinfo -m switch-1
<module> <presence> <pwrState> <health> <svcTag> <nodeId>
Switch-1 Present ON OK 0000000 N/A
48 RACADM Subcommand Details