CLI Guide

cfgChassisPowerCapFPercent =100%
cfgChassisRedundancyPolicy=0
cfgChassisDynamicPSUEngagementEnable=0
# cfgChassisInMaxPowerCapacity=0 W
# cfgChassisInRedundancyReserve=0 W
# cfgChassisInPowerServerAllocation=0 W
# cfgChassisInfrastructureInPowerAllocation=51 W
# cfgChassisTotalInPowerAvailable=0 W
# cfgChassisStandbyInPowerCapacity=0 W
# cfgChassisPowerClear=******** (Write-Only)
# cfgChassisPowerClearTimestamp=18:00:00 12/31/1969
cfgChassisServerBasedPowerMgmtMode=0
cfgChassisPowerButtonEnable=1
cfgChassisAllow110VACOperation=0
cfgChassisMaxPowerConservationMode=0
cfgChassisPerformanceOverRedundancy=1
# cfgSystemEnergyConsumptionClear = ****(Write-Only)
cfgChassisServerBasedPowerMgmtMode=0
racadm config -g cfgChassisPower o cfgChassisPowerClear 1
Clears cfgChassisMinPower and cfgChassisPeakPower.
cfgChassisACPowerRecoveryDisable
Description
If AC power recovery is disabled, the chassis is powered o after power outage is restored.
Legal Values
0 — Enable
1 — Disable
Default
0
cfgThermal
This group displays and congures the thermal settings. Use this object with the cong or getcong subcommands.
To set the congurations, you must have the Chassis Conguration Administrator privileges.
cfgThermalMFSPercent (Read or Write)
Description
Congures the minimum fan speed in percent.
Legal Values
0 to 100
Default
0
cfgThermalEnhancedCoolingMode (Read or Write)
Description
Congures the enhanced cooling mode.
Legal Values
1 — Enabled
0 — Disabled
138 CMC Property Database Group and Object Descriptions