CLI Guide
cfgChassisPowerCapFPercent =100%
cfgChassisRedundancyPolicy=0
cfgChassisDynamicPSUEngagementEnable=0
# cfgChassisInMaxPowerCapacity=0 W
# cfgChassisInRedundancyReserve=0 W
# cfgChassisInPowerServerAllocation=0 W
# cfgChassisInfrastructureInPowerAllocation=51 W
# cfgChassisTotalInPowerAvailable=0 W
# cfgChassisStandbyInPowerCapacity=0 W
# cfgChassisPowerClear=******** (Write-Only)
# cfgChassisPowerClearTimestamp=18:00:00 12/31/1969
cfgChassisServerBasedPowerMgmtMode=0
cfgChassisPowerButtonEnable=1
cfgChassisAllow110VACOperation=0
cfgChassisMaxPowerConservationMode=0
cfgChassisPerformanceOverRedundancy=1
# cfgSystemEnergyConsumptionClear = ****(Write-Only)
cfgChassisServerBasedPowerMgmtMode=0
• racadm config -g cfgChassisPower ‑o cfgChassisPowerClear 1
Clears cfgChassisMinPower and cfgChassisPeakPower.
cfgChassisACPowerRecoveryDisable
Description
If AC power recovery is disabled, the chassis is powered o after power outage is restored.
Legal Values
• 0 — Enable
• 1 — Disable
Default
0
cfgThermal
This group displays and congures the thermal settings. Use this object with the cong or getcong subcommands.
To set the congurations, you must have the Chassis Conguration Administrator privileges.
cfgThermalMFSPercent (Read or Write)
Description
Congures the minimum fan speed in percent.
Legal Values
0 to 100
Default
0
cfgThermalEnhancedCoolingMode (Read or Write)
Description
Congures the enhanced cooling mode.
Legal Values
• 1 — Enabled
• 0 — Disabled
138 CMC Property Database Group and Object Descriptions