CLI Guide
Default
None
cfgChassisInRedundancyReserve (Read Only)
Description
Indicates the amount of redundant power (in watts) in reserve that can be used in the event if an AC grid or PSU is
unsuccessful. This value is 0 if the Redundancy Policy is set to 0 (no redundancy).
Legal Values
0 — (disabled)
1 — (enabled)
Default
None
cfgChassisInPowerServerAllocation (Read Only)
Description
Indicates (in watts) the cumulative power allocated to servers. There is no default as this parameter is specic to the
particular customer conguration.
Legal Values
None
Default
None
cfgChassisInfrastructureInPowerAllocation (Read Only)
Description
Indicates the estimated cumulative DC output power consumption (in watts), determined from a eld replaceable
unit (FRU) on the hardware modules in the chassis.
Legal Values
None
Default
None
cfgChassisTotalInPowerAvailable (Read Only)
Description
Indicates the amount of power (in watts) available for use by the chassis.
Legal Values
None
Default
None
cfgChassisStandbyInPowerCapacity (Read Only)
Description
Indicates the amount of power (in watts) available for powering up any hardware modules that are either added to
the chassis or powered up (if they are already present in the chassis).
Legal Values
None
136 CMC Property Database Group and Object Descriptions