cfgChassisPowerCapFPercent (Read or Write)
Description
Indicates the power consumption limit as a percentage. The percentage is computed mathematically as the minimum
power + (percent * (maximum power — minimum power)). Use cfgChassisPowerCapFPercent when power
consumption is changes regardless of whether server throttling is required.
Legal Values
16–100
NOTE: If the specied percent is lower than the minimum value, the CMC sets the value to the minimum
value.
Default
100
cfgChassisRedundancyPolicy (Read or Write)
Description
Sets the redundancy policy of the chassis.
Legal Values
0 — No redundancy
1 — Grid redundancy
2 — Power supply redundancy
Default
0 — No redundancy
cfgChassisDynamicPSUEngagementEnable (Read or Write)
Description
Enables or disables dynamic engagement.
Legal Values
0 — Disabled
1 — Enabled
Default 0
cfgChassisAllow110VACOperation (Read or Write)
Description
Enables or disables normal chassis power allocations when any PSU is connected to 110V AC service. If disabled and
110V power supplies are detected, all subsequent server power allocation requests are denied. In this mode more
servers cannot be powered on, regardless of server priority.
Legal Values
0 — Disabled
1 — Enabled
Default
0
134 CMC Property Database Group and Object Descriptions