CLI Guide
• 2 — PSU Redundancy
Default 0
cfgChassisDefaultPowerCapLowerBoundBTU (Read Only)
Description
Displays the default power cap lower bound value using British Thermal Unit (BTU).
Legal Values
None
Default
9263 BTU/h
cfgChassisDefaultPowerCapLowerBound (Read Only)
Description
Displays the default power cap lower bound value.
Legal Values
None
Default
2715 W
cfgChassisDefaultPowerCapUpperBound (Read Only)
Description
Displays the default power cap upper bound value.
Legal Values
None
Default
16685 W
cfgChassisDefaultPowerCapUpperBoundBTU (Read or Write)
Description
Displays the default power cap upper bound value using British Thermal Unit (BTU).
Legal Values
None
Default
56931 BTU/h
cfgChassisPowerCap (Read or Write)
Description
Indicates the maximum power consumption limit (in watts) for the entire chassis. The command generates an error if
server throttling is necessary to achieve the power goal based on the value for this setting.
Legal Values
2715–16685 watts
Default
16685 watts