CLI Guide
Table Of Contents
- Dell Chassis Management Controller Version 6.0 for PowerEdge M1000e RACADM CLI Guide
- Contents
- Introduction
- RACADM Subcommand Details
- Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands
- Racadm help and help with subcommand
- help and help subcommand
- arp
- chassisaction
- chassislog
- closessn
- clrraclog
- clrsel
- cmcchangeover
- config
- connect
- deploy
- eventfilters
- feature
- featurecard
- fwupdate
- get
- getactiveerrors
- getarraycfg
- getassettag
- getchassisname
- getconfig
- getdcinfo
- getflexaddr
- getfanreqinfo
- getioinfo
- getkvminfo
- getled
- getmacaddress
- getmodinfo
- getniccfg
- getpbinfo
- getpminfo
- getraclog
- getractime
- getredundancymode
- getsel
- getsensorinfo
- getslotname
- getssninfo
- getsvctag
- getsysinfo
- gettracelog
- getversion
- ifconfig
- krbkeytabupload
- netstat
- ping
- ping6
- racdump
- racreset
- racresetcfg
- remoteimage
- set
- serveraction
- setarraycfg
- setassettag
- setchassisname
- setflexaddr
- setled
- setniccfg
- setractime
- setslotname
- setsysinfo
- sshpkauth
- sslcertdownload
- sslcertupload
- sslcertview
- sslcsrgen
- sslresetcfg
- testemail
- testfeature
- testtrap
- traceroute
- traceroute6
- CMC Property Database Group and Object Descriptions
- Displayable Characters
- idRacInfo
- cfgLanNetworking
- cfgRemoteHosts
- cfgUserAdmin
- cfgEmailAlert
- cfgSessionManagement
- cfgSerial
- cfgOobSnmp
- cfgTraps
- cfgRacTuning
- cfgServerInfo
- cfgActiveDirectory
- cfgLDAP
- cfgLDAPRoleGroup
- cfgStandardSchema
- cfgLocation
- cfgChassisPower
- cfgChassisDefaultPowerCapLowerBoundBTU (Read Only)
- cfgChassisDefaultPowerCapLowerBound (Read Only)
- cfgChassisDefaultPowerCapUpperBound (Read Only)
- cfgChassisDefaultPowerCapUpperBoundBTU (Read or Write)
- cfgChassisAllow110VACOperationTimestamp (Read Only)
- cfgChassisMaxPowerConservationModeTimestamp (Read Only)
- cfgChassisACPowerRecoveryDisable
- cfgThermal
- cfgKVMInfo
- cfgLcdInfo
- cfgAlerting
- cfgIPv6LanNetworking
- cfgCurrentLanNetworking (Read Only)
- cfgCurrentIPv6LanNetworking (Read Only)
- cfgNetTuning
- cfgRacSecurity
- cfgQuickDeploy
- cfgActionOnServerInsertion
- cfgSetiDRACRootPasswordOnServerInsertion
- cfgiDRACRootPassword
- cfgEnableiDRACLAN
- cfgEnableiDRACIPv4
- cfgEnableiDRACIPMIOverLAN
- cfgEnableiDRACIPv4DHCP
- cfgStartingiDRACIPv4Address
- cfgiDRACIPv4GateWay
- cfgiDRACIPv4Netmask
- cfgEnableiDRACIPv6
- cfgEnableiDRACIPv6AutoConfig
- cfgiDRACIPv6PrefixLength
- cfgiDRACIPv6Gateway
- cfgReservedIPAddressNumbers
- cfgUseCMCDNSSettings

CMC N/A Present 34:17:EB:E6:E
0:24
N/A Factory
server-1
-A
10 GbE KR Not
Installed
10:98:36:AC:7
0:EB
Not Installed Not
Installed
Server-2 Not
Installed
Not Present Not
Installed
Not Installed Not
Installed
Server-3
-A
Reserved Present
Switch-4 Not
Installed
Not Present Not
Installed
Not Installed Not
Installed
Switch-1 Not
Installed
Not Present Not Installed N/A N/A
NOTE: If the I/O Modules in slots 1 and 2 are absent and the getmacaddress -a and getmacaddress —c all
commands are run, the output is displayed as Not Installed in the following columns:
● <Presence>
● <NIC1 MAC Address>
● <NIC2 MAC Address>
getmodinfo
Description
Displays configuration and status information for all modules or a specified module (server, switch, CMC,
fan unit, power supply unit (PSU), KVM, or I2C cable) in the chassis.
A power state of "Primary" denotes Active CMC.
To run this subcommand, you must have the CMC Login User privilege.
NOTE: The Service tag field is blank for modules that do not have service tag.
Synopsis
racadm getmodinfo [-m <module>] [-A]
Input
● -m <module> — Specifies the module whose configuration and status information you want to view.
The default command (no options) displays information about all major components in the chassis.
<module> may be any of the following values:
○ server-<n> where n=1–16
○ server-<nx> where n=1–8; x = a, b, c, d
○ switch-<n> where n=1–6
○ cmc-<n> where n=1–2
○ fan-<n> where n=1–9
○ ps-<n> where n=1–6
○ chassis
○ kvm
○ io-cable
○ fpc-cable
● -A — Suppresses headers or labels in the output.
54 RACADM Subcommand Details