CLI Guide
Table Of Contents
- Dell Chassis Management Controller Version 6.0 for PowerEdge M1000e RACADM CLI Guide
- Contents
- Introduction
- RACADM Subcommand Details
- Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands
- Racadm help and help with subcommand
- help and help subcommand
- arp
- chassisaction
- chassislog
- closessn
- clrraclog
- clrsel
- cmcchangeover
- config
- connect
- deploy
- eventfilters
- feature
- featurecard
- fwupdate
- get
- getactiveerrors
- getarraycfg
- getassettag
- getchassisname
- getconfig
- getdcinfo
- getflexaddr
- getfanreqinfo
- getioinfo
- getkvminfo
- getled
- getmacaddress
- getmodinfo
- getniccfg
- getpbinfo
- getpminfo
- getraclog
- getractime
- getredundancymode
- getsel
- getsensorinfo
- getslotname
- getssninfo
- getsvctag
- getsysinfo
- gettracelog
- getversion
- ifconfig
- krbkeytabupload
- netstat
- ping
- ping6
- racdump
- racreset
- racresetcfg
- remoteimage
- set
- serveraction
- setarraycfg
- setassettag
- setchassisname
- setflexaddr
- setled
- setniccfg
- setractime
- setslotname
- setsysinfo
- sshpkauth
- sslcertdownload
- sslcertupload
- sslcertview
- sslcsrgen
- sslresetcfg
- testemail
- testfeature
- testtrap
- traceroute
- traceroute6
- CMC Property Database Group and Object Descriptions
- Displayable Characters
- idRacInfo
- cfgLanNetworking
- cfgRemoteHosts
- cfgUserAdmin
- cfgEmailAlert
- cfgSessionManagement
- cfgSerial
- cfgOobSnmp
- cfgTraps
- cfgRacTuning
- cfgServerInfo
- cfgActiveDirectory
- cfgLDAP
- cfgLDAPRoleGroup
- cfgStandardSchema
- cfgLocation
- cfgChassisPower
- cfgChassisDefaultPowerCapLowerBoundBTU (Read Only)
- cfgChassisDefaultPowerCapLowerBound (Read Only)
- cfgChassisDefaultPowerCapUpperBound (Read Only)
- cfgChassisDefaultPowerCapUpperBoundBTU (Read or Write)
- cfgChassisAllow110VACOperationTimestamp (Read Only)
- cfgChassisMaxPowerConservationModeTimestamp (Read Only)
- cfgChassisACPowerRecoveryDisable
- cfgThermal
- cfgKVMInfo
- cfgLcdInfo
- cfgAlerting
- cfgIPv6LanNetworking
- cfgCurrentLanNetworking (Read Only)
- cfgCurrentIPv6LanNetworking (Read Only)
- cfgNetTuning
- cfgRacSecurity
- cfgQuickDeploy
- cfgActionOnServerInsertion
- cfgSetiDRACRootPasswordOnServerInsertion
- cfgiDRACRootPassword
- cfgEnableiDRACLAN
- cfgEnableiDRACIPv4
- cfgEnableiDRACIPMIOverLAN
- cfgEnableiDRACIPv4DHCP
- cfgStartingiDRACIPv4Address
- cfgiDRACIPv4GateWay
- cfgiDRACIPv4Netmask
- cfgEnableiDRACIPv6
- cfgEnableiDRACIPv6AutoConfig
- cfgiDRACIPv6PrefixLength
- cfgiDRACIPv6Gateway
- cfgReservedIPAddressNumbers
- cfgUseCMCDNSSettings

Table 3. eventfilters (continued)
● Display eventfilter configurations for a specific severity and subcategory. For example, a
severity of warning in the subcategory licensing under audit category:
racadm eventfilters get -c cmc.alert.audit.lic.warning
● Clear all available alert settings:
racadm eventfilters set -c cmc.alert.all -n none
● Configure using severity as a parameter. For example, all informational events in storage
category are assigned poweroff as action, and email and snmp as notifications:
racadm eventfilters set -c cmc.alert.storage.info -n email,snmp
● Configure using subcategory as a parameter. For example, all configurations under the
licensing subcategory in the audit category are assigned poweroff as action and all
notifications are enabled:
racadm eventfilters set -c cmc.alert.audit.lic -n all
● Configure using subcategory and severity as parameters. For example, all Information
events under the licensing subcategory in the audit category are assigned poweroff as
action and all notifications are disabled:
racadm eventfilters set -c cmc.alert.audit.lic.info -n none
feature
Description
Displays all active chassis features. The information displayed includes feature name, date activated and
the serial number of the SD card used to activate the feature.
Dell Feature Cards may contain more than a feature. After any feature included on a Dell Feature Card
is activated on a chassis, any other features that may be included on that Dell Feature Card cannot be
activated on a different chassis.
NOTE: To use this subcommand to deactivate FlexAddress, you must have the Chassis Configuration
Administrator privilege. A user with login privileges can view status only.
NOTE: To deactivate FlexAddress features, the chassis must be turned off.
Synopsis
● racadm feature -s
●
racadm feature -d -c <featurename>
● racadm feature -r -c ExtendedStorage
Input
-s
–Displays the status of active features.
-d
–Deactivates feature specified in -c option.
NOTE: When the FlexAddress and FlexAddressPlus feature are active, deactivating one of them results
in deactivation of the other feature also.
-r
—Reformats damaged or unformatted extended storage media.
26 RACADM Subcommand Details