CLI Guide
Table Of Contents
- Dell Chassis Management Controller Version 6.0 for PowerEdge M1000e RACADM CLI Guide
- Contents
- Introduction
- RACADM Subcommand Details
- Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands
- Racadm help and help with subcommand
- help and help subcommand
- arp
- chassisaction
- chassislog
- closessn
- clrraclog
- clrsel
- cmcchangeover
- config
- connect
- deploy
- eventfilters
- feature
- featurecard
- fwupdate
- get
- getactiveerrors
- getarraycfg
- getassettag
- getchassisname
- getconfig
- getdcinfo
- getflexaddr
- getfanreqinfo
- getioinfo
- getkvminfo
- getled
- getmacaddress
- getmodinfo
- getniccfg
- getpbinfo
- getpminfo
- getraclog
- getractime
- getredundancymode
- getsel
- getsensorinfo
- getslotname
- getssninfo
- getsvctag
- getsysinfo
- gettracelog
- getversion
- ifconfig
- krbkeytabupload
- netstat
- ping
- ping6
- racdump
- racreset
- racresetcfg
- remoteimage
- set
- serveraction
- setarraycfg
- setassettag
- setchassisname
- setflexaddr
- setled
- setniccfg
- setractime
- setslotname
- setsysinfo
- sshpkauth
- sslcertdownload
- sslcertupload
- sslcertview
- sslcsrgen
- sslresetcfg
- testemail
- testfeature
- testtrap
- traceroute
- traceroute6
- CMC Property Database Group and Object Descriptions
- Displayable Characters
- idRacInfo
- cfgLanNetworking
- cfgRemoteHosts
- cfgUserAdmin
- cfgEmailAlert
- cfgSessionManagement
- cfgSerial
- cfgOobSnmp
- cfgTraps
- cfgRacTuning
- cfgServerInfo
- cfgActiveDirectory
- cfgLDAP
- cfgLDAPRoleGroup
- cfgStandardSchema
- cfgLocation
- cfgChassisPower
- cfgChassisDefaultPowerCapLowerBoundBTU (Read Only)
- cfgChassisDefaultPowerCapLowerBound (Read Only)
- cfgChassisDefaultPowerCapUpperBound (Read Only)
- cfgChassisDefaultPowerCapUpperBoundBTU (Read or Write)
- cfgChassisAllow110VACOperationTimestamp (Read Only)
- cfgChassisMaxPowerConservationModeTimestamp (Read Only)
- cfgChassisACPowerRecoveryDisable
- cfgThermal
- cfgKVMInfo
- cfgLcdInfo
- cfgAlerting
- cfgIPv6LanNetworking
- cfgCurrentLanNetworking (Read Only)
- cfgCurrentIPv6LanNetworking (Read Only)
- cfgNetTuning
- cfgRacSecurity
- cfgQuickDeploy
- cfgActionOnServerInsertion
- cfgSetiDRACRootPasswordOnServerInsertion
- cfgiDRACRootPassword
- cfgEnableiDRACLAN
- cfgEnableiDRACIPv4
- cfgEnableiDRACIPMIOverLAN
- cfgEnableiDRACIPv4DHCP
- cfgStartingiDRACIPv4Address
- cfgiDRACIPv4GateWay
- cfgiDRACIPv4Netmask
- cfgEnableiDRACIPv6
- cfgEnableiDRACIPv6AutoConfig
- cfgiDRACIPv6PrefixLength
- cfgiDRACIPv6Gateway
- cfgReservedIPAddressNumbers
- cfgUseCMCDNSSettings

# cfgServerInfoIndex=1a
# cfgServerSlotNumber=1a
# cfgServerServiceTag=ABC1234
cfgServerName=SLOT-01a
# cfgServerFW=1.57.57 (Build 04)
# cfgServerBIOS=2.3.3
# cfgServerBmcMacAddress=F8:DB:88:3E:1A:00
# cfgServerNic1MacAddress=F8:DB:88:3E:1A:01
# cfgServerNic2MacAddress=F8:DB:88:3E:1A:04
cfgServerPriority=1
cfgServerNicEnable=0
cfgServerIPMIOverLANEnable=0
# cfgServerPowerBudgetAllocation=246
cfgServerDNSRegisterIMC=0
cfgServerDNSIMCName=idrac-ABCD1234
# cfgServerRootPassword=******** (Write-Only)
cfgServerFirstBootDevice=0
cfgServerBootOnce=1
# cfgServerPowerConsumption=84
cfgActiveDirectory
This group contains parameters to configure CMC Active Directory feature.
Use this object with the config or getconfig subcommands.
To use this object property, you must have the Chassis Configuration Administrator privilege.
NOTE:
You can configure a setting that does not have the hash sign (#) prefixed in the output. To modify a configurable
object, use the —o option.
The following sections provide information about the objects in the cfgActiveDirectory.
cfgADRacDomain (Read or Write)
Description
Active Directory Domain in which CMC resides.
Legal Values
Any printable text string of up to 254 characters, with no white space.
Default
<blank>
cfgADRacName (Read or Write)
Description
Name of CMC as recorded in the Active Directory forest.
Legal Values
Any printable text string of up to 254 characters, with no white space.
Default
<blank>
CMC Property Database Group and Object Descriptions 127