Release Notes

Known Issues
Issue 1:
Description
XWKGY_Intel10G card shows Flex disabled address after racresetcfg of CMC in Network Device page and
OS.
Resolution
Virtual reseat or Physical reseat of the server.
Versions/Systems Affected
All CMC versions including CMC 5.22 and PowerEdge servers with iDRAC7 or earlier.
Issue 2:
Description
An error occurs while importing CMC configuration file using local racadm or remote racadm.
Resolution
This issue occurs when IPv6 is enabled or disabled from the configuration file. Enable or disable IPv6 using
the command,racadm config -g cfgIPv6LanNetworking -o cfgIPv6Enable 0”.
Versions/Systems Affected
CMC version 5.11 or later
Issue 3:
Description
When CMC firmware is downgraded to 4.50 from 5.00 or later while network share is configured, the Server
Components Update page gets corrupted.
Resolution
Clear the network configuration before downgrading to 4.50
Versions/Systems Affected
CMC version 4.50 or earlier
Limitations
Issue 1:
Description
While executing WSMan commands continuously, some commands may timeout occasionally, but get
resolved quickly without CMC failover or reboot.
Resolution
None
Versions/Systems Affected
All CMC versions including CMC 5.22
Issue 2:
Description
In the Microsoft Edge browser, the Boot Identity Profiles page in the CMC GUI is slow when 1500 or more
MAC addresses are created from the MAC pool for the Boot Identity profile.
Resolution
Create less than 1500 MAC address in the Microsoft Edge browser. Use other supported browsers for more
than 1500 MAC addresses.
Versions/Systems Affected
CMC version 5.11 or later