Visualización de versiones de rmware actualmente instaladas
mediante RACADM
Para ver las versiones de rmware instaladas actualmente mediante RACADM, utilice el subcomando getkvminfo. Para obtener más
información, consulte Chassis Management Controller for Dell PowerEdge M1000e RACADM Command Line Reference Guide (Guía de
referencia de la línea de comandos RACADM de Chassis Management Controller para Dell PowerEdge M1000e).
Updating CMC Firmware
You can update CMC rmware using Web interface or RACADM. The rmware update, by default, retains the current CMC settings. During
the update process, you can reset CMC conguration settings back to the factory default settings.
NOTE: To update rmware on CMC, you must have Chassis Conguration Administrator privilege.
If a Web user interface session is used to update system component rmware, the Idle Timeout setting must be set high enough to
accommodate the le transfer time. In some cases, the rmware le transfer time may be as high as 30 minutes. To set the Idle Timeout
value, see
Conguring Services.
During updates of CMC rmware, it is normal for some or all of the fan units in the chassis to spin at 100%.
If you have redundant CMCs installed in the chassis, it is recommended to update both the CMCs to the same rmware version at the
same time with a single operation. If CMCs have dierent rmware and a failover occurs, unexpected results may occur.
NOTE
: CMC rmware update or roll back is supported only for the rmware versions 3.10, 3.20, 3.21, 4.0, 4.10, 4.11, 4.30, 4.31,
4.45, 4.5, 5.0, and later. For any version other than these, rst update to any of these versions, and then update to the required
version.
The Active CMC resets and becomes temporarily unavailable after the rmware has been uploaded successfully. If a standby CMC is
present, the standby and active roles swap. The standby CMC becomes the active CMC. If an update is applied only to the active CMC,
after the reset is complete, the active CMC does not run the updated image, only the standby CMC has that image. In general, it is highly
recommended to maintain identical rmware versions for the active and standby CMCs.
When the standby CMC has been updated, swap the CMCs’ roles so that the newly updated CMC becomes the active CMC and CMC
with the older rmware becomes the standby. See the cmcchangeover command section in the Chassis Management Controller for Dell
PowerEdge M1000e RACADM Command Line Reference Guide
.
information about swapping roles. This allows you to verify that the update has succeeded and that the new rmware is working properly,
before you update the rmware in the second CMC. When both CMCs are updated, you can use the cmcchangeover command to
restore the CMCs to their previous roles. CMC Firmware revision 2.x updates both the primary CMC and the redundant CMC without
using the cmcchangeover command.
To avoid disconnecting other users during a reset, notify authorized users who may log in to CMC and check for active sessions in the
Sessions page. To open the Sessions page, select Chassis in the tree, click the Network tab, and then click the Sessions subtab.
When transferring les to and from CMC, the le transfer icon spins during the transfer. If your icon is animated, make sure that your
browser is congured to allow animations. For instructions, see Allow Animations in Internet Explorer.
If you experience problems downloading les from CMC using Internet Explorer, enable the Do not save encrypted pages to disk option. For
instructions, see Downloading Files From CMC With Internet Explorer.
Related links
Descarga de rmware del CMC
Visualización de versiones de rmware actualmente instaladas
Actualización de
rmware 49