Users Guide

WWN/MAC Addresses
The WWN/MAC Address section displays the WWN/MAC information that is assigned to all servers, even if those server slots are
currently empty.
Location displays the location of the slot occupied by the Input/Output modules. The six slots are identied by a combination of the
group name (A, B, or C) and slot number (1 or 2): slot names A1, A2, B1, B2, C1, or C2. iDRAC is the server's integrated management
controller.
Fabric displays the type of the I/O fabric.
Server-Assigned displays the server-assigned WWN/MAC addresses embedded in the controller's hardware.
Chassis-Assigned displays the chassis-assigned WWN/MAC addresses used for the particular slot.
A green check mark in the Server-Assigned or in Chassis-Assigned columns indicates the type of active addresses. Chassis-assigned
addresses are assigned when FlexAddress is activated on the chassis, and represents the slot-persistent addresses. When
ChassisaAssigned addresses are checked, those addresses are used even if one server is replaced with another server.
Mensajes de comandos
En la siguiente tabla se muestran los comandos RACADM y los mensajes de situaciones comunes de FlexAddress.
Tabla 39. Comandos y mensajes de salida de FlexAddress
Situación Comando Salida
La tarjeta SD en el módulo CMC activo
está vinculada a otra etiqueta de servicio.
$racadm featurecard -s
The feature card inserted is
valid and contains the following
feature(s)
FlexAddress: The feature card is
bound to another chassis, svctag
= <Service tag Number> SD card
SN = <Valid flex address serial
number>
La tarjeta SD en el módulo CMC activo
está vinculada a la misma etiqueta de
servicio.
$racadm featurecard -s
The feature card inserted is
valid and contains the following
feature(s)
FlexAddress: The feature card is
bound to this chassis
La tarjeta SD en el módulo CMC activo no
está vinculada a ninguna etiqueta de
servicio.
$racadm featurecard -s
The feature card inserted is
valid and contains the following
feature(s)
FlexAddress: The feature card is
not bound to any chassis
Función FlexAddress no activada en el
chasis por algún motivo (no hay tarjeta SD
insertada, tarjeta SD dañada, después
haber desactivado la función, tarjeta SD
vinculada a otro chasis).
$racadm setflexaddr [-f
<fabricName> <slotState>]
$racadm setflexaddr [-i <slot#>
<slotstate>]
ERROR: Flexaddress feature is
not active on the chassis
El usuario invitado intenta congurar
FlexAddress en ranuras o redes Fabric.
$racadm setflexaddr [-f
<fabricName> <slotState>]
ERROR: Insufficient user
privileges to perform operation
Uso de las tarjetas FlexAddress y FlexAddress Plus 189