Severity Message Cause
received from Host) and the action is set to power
cycle.
Critical Log is full. The SEL device detects that only one entry can be
added to the SEL before it is full.
Warning Persistent correctable memory errors detected on
a memory device at location <location>.
Warning Persistent correctable memory error rate has
increased for a memory device at location
<location>.
Correctable ECC errors reach a critical rate.
Critical Multi-bit memory errors detected on a memory
device at location <location>.
An uncorrectable ECC error was detected.
Critical An I/O channel check NMI was detected on a
component at bus <number> device <number>
function <number>.
A critical interrupt is generated in the I/O Channel.
Critical An I/O channel check NMI wa detected on a
component at slot <number>.
A critical interrupt is generated in the I/O Channel.
Critical A PCI parity error was detected on a component at
bus <number> device <number> function
<number>.
Parity error was detected on the PCI bus.
Critical A PCI parity error was detected on a component at
slot <number>.
Parity error was detected on the PCI bus.
Critical A PCI system error was detected on a component
at bus <number> device <number> function
<number>.
PCI error detected by device.
Critical A PCI system error was detected on a component
at slot <number>.
PCI error detected by device.
Critical Persistent correctable memory error logging
disabled for a memory device at location
<location>.
Single bit error logging is disable when too many SBE get
logged for a memory device.
Critical All event logging is disabled.
Non- Recoverable CPU protocol error detected. The processor protocol entered a non-recoverable state.
Non- Recoverable CPU bus parity error detected. The processor bus PERR entered a non-recoverable
state.
Non- Recoverable CPU initialization error detected. The processor initialization entered a non-recoverable
state.
Non- Recoverable CPU machine check detected. The processor machine check entered a non-
recoverable state.
Critical Memory redundancy is lost.
Critical A bus fatal error was detected on a component at
bus <number> device <number> function
<number>.
Fatal error is detected on the PCIe bus.
Critical A software NMI was detected on a component at
bus <number> device <number> function
<number>.
Chip error is detected.