Users Guide
2
Installing and Setting Up CMC
This section provides information about how to install the PowerEdge M1000e Chassis Management Controller (CMC) hardware,
establish access to CMC, configure your management environment to use CMC, and guides you through the next steps for
configuring the CMC:
• Set up initial access to CMC.
• Access CMC through a network.
• Add and configure CMC users.
• Update CMC firmware.
For more information about installing and setting up redundant CMC environments, see Understanding Redundant CMC
Environment.
Before You Begin
Before setting up your CMC environment, download the latest version of CMC firmware from support.dell.com.
Also, make sure that you have the Dell Systems Management Tools and Documentation DVD that was included with your system.
Installing CMC Hardware
CMC is pre-installed on your chassis and hence no installation is required. You can install a second CMC to run as a standby to the
active CMC.
Related links
Understanding Redundant CMC Environment
Checklist To Set up Chassis
The following steps enable you to setup the chassis accurately:
1. Ensure that, CMC and the management station where you use your browser are on the same network, which is called the
management network. Connect an Ethernet network cable from the CMC port labelled GB to the management network.
NOTE: Do not place a cable in CMC Ethernet port labelled STK. For more information to cable the STK port, see
Understanding Redundant CMC Environment.
2. Install the I/O modules in the chassis and connect the cables.
3. Insert the servers in the chassis.
4. Connect the chassis to the power source.
5. Push the power button at the lower left corner of the chassis or power on the chassis from the CMC Web interface after
completing step 7.
NOTE: Do not turn on the servers.
6. Using the LCD panel on the front of the system, provide CMC with a static IP address or configure it for DHCP.
7. Connect to the CMC IP address and provide default username (root) and password (calvin).
8. Provide each iDRAC with an IP address in the CMC Web interface and enable the LAN and IPMI interface.
NOTE: iDRAC LAN interface on some servers are disabled by default.
9. Provide each I/O module with an IP address in the CMC Web interface.
23