Users Guide

Privilege Description
Configure Users:
Set iDRAC root password
iDRAC reset
Server Control Administrator:
Power on
Power off
Power cycle
Graceful shutdown
Server Reboot
Test Alert User User can send test alert messages.
Debug Command Administrator User can execute system diagnostic commands.
Fabric A Administrator User can set and configure the Fabric A IOM, which resides in either slot A1 or slot
A2 of the I/O slots.
Fabric B Administrator User can set and configure the Fabric B IOM, which resides in either slot B1 or slot
B2 of the I/O slots.
Fabric C Administrator User can set and configure the Fabric C IOM, which resides in either slot C1 or slot
C2 of the I/O slots.
The CMC user groups provide a series of user groups that have pre-assigned user privileges.
NOTE: If you select Administrator, Power User, or Guest User, and then add or remove a privilege from the pre-defined
set, the CMC Group automatically changes to Custom.
Table 20. : CMC Group Privileges
User Group Privileges Granted
Administrator
CMC Login User
Chassis Configuration Administrator
User Configuration Administrator
Clear Logs Administrator
Server Administrator
Test Alert User
Debug Command Administrator
Fabric A Administrator
Fabric B Administrator
Fabric C Administrator
Power User
Login
Clear Logs Administrator
Chassis Control Administrator (Power commands)
Server Administrator
Test Alert User
Fabric A Administrator
Fabric B Administrator
Fabric C Administrator
Guest User Login