Users Guide
Table 18. Event Traps Filter Masks
Event Filter Mask Value
Fan Probe Failure 0x1
Battery Probe Warning 0x2
Temperature Probe Warning 0x8
Temperature Probe Failure 0x10
Redundancy Degraded 0x40
Redundancy Lost 0x80
Power Supply Warning 0x800
Power Supply Failure 0x1000
Power Supply Absent 0x2000
Hardware Log Failure 0x4000
Hardware Log Warning 0x8000
Server Absent 0x10000
Server Failure 0x20000
KVM Absent 0x40000
KVM Failure 0x80000
IOM Absent 0x100000
IOM Failure 0x200000
Firmware Version Mismatch 0x400000
Chassis Power Threshold Error 0x1000000
SDCARD Absent 0x2000000
SDCARD Error 0x4000000
Chassis Group Error 0x8000000
Server Sleeve Absent 0x10000000
Fabric Mismatch 0x20000000
4. Enable traps alerts:
racadm config -g cfgTraps -o cfgTrapsEnable 1 -i <index>
where <index> is a value between 1–4. CMC uses the index number to distinguish up to four configurable destinations for
traps alerts. Destinations may be specified as appropriately formatted numeric addresses (IPv6 or IPv4), or Fully-Qualified
Domain Names (FQDNs).
5. Specify a destination IP address to receive the traps alert:
racadm config -g cfgTraps -o cfgTrapsAlertDestIPAddr <IP address> -i <index>
where <IP address> is a valid destination, and <index> is the index value specified in step 4.
6. Specify the community name:
racadm config -g cfgTraps -o cfgTrapsCommunityName <community name> -i <index>
where <community name> is the SNMP community to which the chassis belongs, and <index> is the index value
specified in steps 4 and 5.
118