Reference Guide

-t: specify the le type to be imported. The valid value is xml. This option is case-insensitive.
Example
Congure event lter congurations from a conguration le using remote racadm
racadm -r 192.168.0.120 -u <username> -p <password> set -f file.txt
Congure a CMC from an XML conguration le on a local share using remote racadm
racadm -r 192.168.0.120 -u <username> -p <password> set -f
myfile.xml -t xml
Congure a CMC from an XML conguration le on a remote CIFS share
racadm set -f myfile.xml -t xml -u myuser -p mypass -l //
192.168.0.0/myshare
Congure a CMC from an XML conguration le on a remote NFS share
racadm set -f myfile.xml -t xml -l 192.168.0.0:/myshare
serveraction
Description Enables you to perform power management operations on the blade system.
To run this subcommand, you must have the Execute Server Control Commands permission.
Synopsis
racadm serveraction -a <action>
racadm serveraction -m <module> <action>
Input
-m <module> — Must be one of the following values:
server–<n>: where n=1–16
server–<nx>: where n=1–8; x=a–d (enter lowercase letter only).
-a — Performs power action on all servers. Not allowed with the powerstatus action.
<action>Species the power management operation to perform. The options are:
hardreset — Performs a force reset (reboot) operation on the managed system.
powercycle — Performs a power-cycle operation on the managed system. This action is similar to
pressing the power button on the systems front panel to turn o and then turn on the system.
NOTE: The -m and -a options are applicable only to CMC platforms.
NOTE: If the server is in turned o state, the powercycle option power-up the server.
powerdown — Powers down the managed system.
powerup — Powers up the managed system.
powerstatus — Displays the current power status of the server (ON or OFF).
graceshutdown — Performs a graceful shutdown of the server. If the operating system on the server
cannot shut down completely, then this operation is not performed.
nmi — Generates the Non-masking interrupt (NMI) to halt the system operation. The NMI sends a high-
level interrupt to the operating system, which causes the system to halt the operation to allow critical
diagnostic or troubleshooting activities.
NOTE:
The halt system operation does not occur on systems running the Linux operating system.
-f — Force the server power management operation.
reseat — Performs virtual reseat of the server. This operation simulates reseating the blade by resetting
the iDRAC on that blade. -f is required for this operation.
NOTE: The actionpowerstatus is not allowed with -a option.
Output
Displays an error message if the requested operation is not completed, or a success message if the operation is
completed.