Reference Guide
7 SLOT-07 ON 120 W 1 PowerEdge M630
8 WIN-HP4N5G1EOCS ON 104 W 1 PowerEdge M630
9 WIN-HP4N5G1EOCS ON 116 W 1 PowerEdge M630
10 SLOT-10 ON 127 W 1 PowerEdge M630
11 SLOT-11 ON 110 W 1 PowerEdge M630
12 SLOT-12 ON 118 W 1 PowerEdge M630
13 SLOT-13 ON 106 W 1 PowerEdge M630
14 SLOT-14 ON 96 W 1 PowerEdge M630
15 SLOT-15 ON 115 W 1 PowerEdge M630
16 SLOT-16 ON 134 W 1 PowerEdge M630
NOTE: Extended Power Performance (EPP) – related elds are displayed even if EPP is disabled.
getpminfo
Description Displays power management status information.
To run this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm getpminfo
Input N/A
Example:
Displays power managemnt status information:
racadm getpminfo
[Real-Time Power Statistics]
System Input Power = 1661 W (5667 BTU/h)
Peak System Power = 1916 W (6537 BTU/h)
Peak System Power Start Time = 09:19:27 11/26/2014
Peak System Power Timestamp = 09:29:20 11/26/2014
Minimum System Power = 35 W (119 BTU/h)
Minimum System Power Start Time = 09:19:27 11/26/2014
Minimum System Power Timestamp = 09:54:00 11/26/2014
System Idle Power = 1661 W (5667 BTU/h)
System Potential Power = 3414 W (11649 BTU/h)
System Input Current Reading = 7.3 A
[Real-Time Energy Statistics]
System Energy Consumption = 1.6 kWh
System Energy Consumption Start Time = 09:19:27 11/26/2014
52