Reference Guide

racadm getioinfo -m switch-<n> -o
Input
-m <module>Species the module or device.<module> must be switch — <n>, where n = 1–6
-s — Displays stack information.
-o — Displays IOA Flex module information. The possible values for the ex module type are:
04x10G Base-T FlexIO Module
14x10G SFP+ FlexIO Module
22x40G QSFP+ FlexIO Module
34xFC FlexIO Module
4No flex module installed
>4Invalid
Example
racadm getioinfo
<IO> <Name> <Type> <Presence> <POST> <Power> <Role> <SecureMode> <Mode>
switch
-1
MXL
10/40GbE
10 GbE KR Present OK ON Master
No
Full
Switch
switch
-2
PowerEdg
e M I/O
Aggregat
or
10 GbE KR Present OK ON Standal
one
No
Standal
one
switch
-3
Brocade
M6505
Fibre
Channel
16
Present OK ON Master
No
Standal
one
switch
-4
Brocade
M6505
Fibre
Channel
16
Present OK ON Master
No
Standal
one
switch
-5
PowerEdg
e M I/O
Aggregat
or
10 GbE KR Present OK ON Standal
one
No
Standal
one
switch
-6
MXL
10/40GbE
10 GbE KR Present OK ON Master
No
Full
Switch
racadm getioinfo -s
<Chassis> <IO> <Slot> <Presence> <Role> <Unit> <Stack ID>
abc1234 Switch-1 A1 Present Master N/A N/A
abc1234 Switch-2 A2 Present Standalone 1 N/A
abc1234 Switch-3 B1 Present Master N/A N/A
abc1234 Switch-4 B2 Present Master N/A N/A
abc1234 Switch-5 C1 Present Standalone 0 N/A
abc1234 Switch-6 C2 Present Master N/A N/A
racadm getioinfo -m switch-1
40