Reference Guide

To run this subcommand, you must have the CMC Login User privilege.
NOTE: If FlexAddress is not activated on the chassis, the command displays server-assigned
MAC/WWN addresses. If the slot is empty, the command enters blank in the server-assigned
MAC/WWN addresses. If an external console controls the MAC/WWN addresses, the command
displays an externally managed message.
Synopsis
racadm getflexaddr [-i <slotNum>]
Input -i <slotNum>Species the slot information that must be displayed. <slotNum> can be from 1 to 16.
Output None
Example
Display current exaddress settings for all slots and fabrics.
racadm getflexaddr
<Slot#> <Status> <Server Presence>
1 Enabled Present
2 Enabled Present
3 Enabled Not Present
4 Enabled Not Present
5 Enabled Present
6 Enabled Not Present
7 Enabled Not Present
8 Enabled Not Present
9 Enabled Not Present
10 Enabled Extension(2)
11 Enabled Not Present
12 Enabled Not Present
13 Enabled Extension(5)
14 Enabled Not Present
15 Enabled Not Present
16 Enabled Not Present
<Fabric> <Type> <Status>
A Gigabit Ethernet Enabled
B None Enabled
C None Enabled
37