Reference Guide
To run this subcommand, you must have the CMC Login User privilege.
NOTE: Fabric verication for server DCs is performed only when the chassis is turned on. When the
chassis is on standby power, iDRACs on the server modules remain turned o and thus are unable to
report the server's DC fabric type. The DC fabric type may not be reported in the CMC user interface
until iDRAC on the server is turned on.
Synopsis
• racadm getdcinfo
• racadm getdcinfo [-n]
Input -n — Displays the model names for the daughter cards in servers.
Example
• The example output below is for a system with multi-slot servers:
racadm getdcinfo
Group A I/O Type : Gigabit Ethernet
Group B I/O Type : Gigabit Ethernet
Group C I/O Type : 10 GbE XAUI
<IO#> <Type> <State> <Role>
switch-1 Gigabit Ethernet OK Master
switch-2 None N/A N/A
switch-3 Gigabit Ethernet OK Master
switch-4 None N/A N/A
switch-5 Gigabit Ethernet OK Member
switch-6 None N/A N/A
<Server#> <Presence> <DC1 Type> <DC1 State> <DC2 Type> <DC2 State>
server-1 Present None N/A None N/A
server-2 Not Present None N/A None N/A
server-3 Not Present None N/A None N/A
server-4 Present None N/A Gigabit
Ethernet
OK
server-5 Not Present None N/A None N/A
server-6 Not Present None N/A None N/A
server-7 Not Present None N/A None N/A
server-8 Present FibreChannel 4 Invalid None N/A
server-9 Extension(1) None N/A None N/A
server-10 Not Present None N/A None N/A
server-11 Not Present None N/A None N/A
35