Reference Guide

<featurename> — must be one of the following:
flexAddress
flexAddressPlus
ExtendedStorage (with -d, or -r)
NOTE: The —a option is not supported for CMC 5.0.
Example
Display the current status of all chassis features:
racadm feature -s
Deactivate the FlexAddressPlus feature on the chassis:
racadm feature -d -c FlexAddressPlus
featurecard
Description Veries proper SD card installation and displays the SD card status.
To use this subcommand, you must have the Chassis Conguration Administrator privilege.
Synopsis
racadm featurecard -s
Input
-s — Lists active SD card features and SD card status.
Output
No feature card insertedAction: To verify that the SD card was properly inserted, check the
CMC. In a redundant CMC conguration, make sure the CMC with the SD feature card installed is the
active CMC and not the standby CMC.
The feature card inserted is valid and contains the following feature(s)
FlexAddress: The feature card is bound to this chassis
Action: No action
required.
No features active on the chassisAction: Install the SD card into the CMC.
The feature card inserted is valid and contains the following feature(s)
FlexAddress: The feature card is bound to another chassis, svctag =
ABC1234, SD card SN = 01122334455
Action: Remove the SD card; locate and install the SD card for the current chassis.
The feature card inserted is valid and contains the following feature(s)
FlexAddress: The feature card is not bound to any chassis
Action: The feature card can be moved to another chassis, or can be reactivated on the current chassis. To
reactivate on the current chassis, enter racadm racreset until the CMC module with the feature card
installed becomes active.
Example
$ racadm featurecard -s
The feature card inserted is valid, serial number TEST0123456789012345678
The feature card contains the following feature(s):
FlexAddress: The feature is bound to this chassis
FlexAddressPlus: The feature is bound to this chassis
ExtendedStorage: The feature is bound to this chassis
fwupdate
Table 5. fwupdate — Details
Description
Allows you to update the rmware on the KVM, active CMC, standby CMC, iDRAC or an IOM infrastructure
device. You can:
Check the rmware update process status.
Update CMC from FTP or TFTP server by providing an IP address and optional path.
25