cfgLocationRackslot (Read or Write)
Description
Indicates slot where server is located.
Legal Values
Values 1–255 (1 Byte)
Default
0
cfgLocationDeviceSize (Read Only)
Description
Indicates server chassis size.
Legal Values
Values 1–255
Default
0
cfgChassisPower
This group contains parameters to display or congure power for the chassis.
Use this object with the cong or getcong subcommands.
To use this object property, you must have the Chassis Conguration Administrator privilege.
NOTE: You can congure a setting that does not have the hash sign (#) prexed in the output. To modify a congurable
object, use the -o option.
The following sections provide information about the objects in the cfgChassisPower group.
NOTE: When updating from a le, update the value for one chassis power cap property and remove the values for the
other chassis power cap properties or, update the last percentage value as it is applicable to all chassis power cap
properties. The chassis power cap properties are: cfgChassisPowerCap, cfgChassisPowerCapF,
cfgChassisPowerCapBTU, cfgChassisPowerCapFBTU, cfgChassisPowerCapPercent, and
cfgChassisPowerCapFPercent.
cfgChassisServerBasedPowerMgmtMode (Read or Write)
Description
Manages the applicable functions by the Power Measure, Mitigate, and Manage Console (PM3).
Legal Values
1 — Enabled
0 — Disabled
Default 0 — Disabled
cfgChassisEPPEnable (Read or Write)
Description
Enables the Extended Power Performance (EPP).
Legal Values
1 — Enabled
0 — Disabled
Default
0 — Disabled