cfgNicVLanEnable (Read or Write)
Description
Enables or disables the VLAN capabilities.
All chassis management traffic, including the CMC and all iDRACs, resides on this external VLAN when
enabled. No iDRAC configuration change is required to use this external management network VLAN.
Legal Values
1 (TRUE)
0 (FALSE)
Default
0
Example
racadm config -g cfgLanNetworking -o cfgNicVLanEnable
1
racadm config -g cfgLanNetworking -o cfgNicVLanEnable
0
cfgNicVLanID (Read or Write)
Description
Specifies the VLAN ID for the network VLAN configuration. This property is only valid if
cfgNicVLanEnable is set to 1(enabled).
Legal Values
14000 and 40214094
Default
1
Example
racadm config -g cfgLanNetworking -o cfgNicVlanID
1
cfgNicVLanPriority (Read or Write)
Description
Specifies the VLAN Priority for the network VLAN configuration. This property is only valid if
cfgNicVLanEnable is set to 1 (enabled).
Legal Values
07
Default
0
Example
racadm config -g cfgLanNetworking -o
cfgNicVLanPriority 7
cfgDNSDomainName (Read or Write)
Description
In the DNS domain name, parameter is only valid if cfgDNSDomainNameFromDHCP is set to 0(FALSE).
Legal Values
A string of up to 254 ASCII characters. At least one of the characters must be alphabetic. Characters are
restricted to alphanumeric, '-', and '.'.
98 CMC Property Database Group and Object Descriptions