Reference Guide
Table Of Contents
- Chassis Management Controller Version 5.2 for Dell PowerEdge M1000e RACADM Command Line Reference Guide
- Contents
- Introduction
- RACADM Subcommand Details
- Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands
- racadm ? and ? subcommand
- help and help subcommand
- arp
- chassisaction
- chassislog
- closessn
- clrraclog
- clrsel
- cmcchangeover
- config
- connect
- deploy
- eventfilters
- feature
- featurecard
- fwupdate
- get
- getactiveerrors
- getarraycfg
- getassettag
- getchassisname
- getconfig
- getdcinfo
- getflexaddr
- getfanreqinfo
- getioinfo
- getkvminfo
- getled
- getmacaddress
- getmodinfo
- getniccfg
- getpbinfo
- getpminfo
- getraclog
- getractime
- getredundancymode
- getsel
- getsensorinfo
- getslotname
- getssninfo
- getsvctag
- getsysinfo
- gettracelog
- getversion
- ifconfig
- krbkeytabupload
- netstat
- ping
- ping6
- racdump
- racreset
- racresetcfg
- remoteimage
- set
- serveraction
- setarraycfg
- setassettag
- setchassisname
- setflexaddr
- setled
- setniccfg
- setractime
- setslotname
- setsysinfo
- sshpkauth
- sslcertdownload
- sslcertupload
- sslcertview
- sslcsrgen
- sslresetcfg
- testemail
- testfeature
- testtrap
- traceroute
- traceroute6
- CMC Property Database Group and Object Descriptions
- Displayable Characters
- idRacInfo
- cfgLanNetworking
- cfgRemoteHosts
- cfgUserAdmin
- cfgEmailAlert
- cfgSessionManagement
- cfgSerial
- cfgOobSnmp
- cfgTraps
- cfgRacTuning
- cfgServerInfo
- cfgActiveDirectory
- cfgLDAP
- cfgLDAPRoleGroup
- cfgStandardSchema
- cfgLocation
- cfgChassisPower
- cfgChassisDefaultPowerCapLowerBoundBTU (Read Only)
- cfgChassisDefaultPowerCapLowerBound (Read Only)
- cfgChassisDefaultPowerCapUpperBound (Read Only)
- cfgChassisDefaultPowerCapUpperBoundBTU (Read or Write)
- cfgChassisAllow110VACOperationTimestamp (Read Only)
- cfgChassisMaxPowerConservationModeTimestamp (Read Only)
- cfgChassisACPowerRecoveryDisable
- cfgThermal
- cfgKVMInfo
- cfgLcdInfo
- cfgAlerting
- cfgIPv6LanNetworking
- cfgCurrentLanNetworking (Read Only)
- cfgCurrentIPv6LanNetworking (Read Only)
- cfgNetTuning
- cfgRacSecurity
- cfgQuickDeploy
- cfgActionOnServerInsertion
- cfgSetiDRACRootPasswordOnServerInsertion
- cfgiDRACRootPassword
- cfgEnableiDRACLAN
- cfgEnableiDRACIPv4
- cfgEnableiDRACIPMIOverLAN
- cfgEnableiDRACIPv4DHCP
- cfgStartingiDRACIPv4Address
- cfgiDRACIPv4GateWay
- cfgiDRACIPv4Netmask
- cfgEnableiDRACIPv6
- cfgEnableiDRACIPv6AutoConfig
- cfgiDRACIPv6PrefixLength
- cfgiDRACIPv6Gateway
- cfgReservedIPAddressNumbers
- cfgUseCMCDNSSettings
● racadm setniccfg [-m <module>] -k [<speed> <duplex>]
● racadm setniccfg [-i <slot>] -v [<vlan_id> <vlan_priority>]
Input
● -d — Enables DHCP for the NIC. It is enabled by default.
● -d6 — Enables AutoConfig for the NIC (default is disabled).
● -s — Enables static IP settings. The IPv4 address, netmask, and gateway must be specified.
Otherwise, the existing static settings are used. <ipaddress>, <netmask>, and <gateway> must
be typed as dot-separated strings.
racadm setniccfg -s 192.168.0 255.255.255.0 192.168.0
● -s6 — Enables static IPv6 settings. The IPv6 address, Prefix Length, and the IPv6 Gateway can be
specified.
● -o — Enable or disable NIC.
●
-m<module> — Must be one of the following values:
○ chassis — Default state if -m is not specified
○ server–<n>: where n=1–16
○ server–<nx>: where n=1–8; x=a–d (lower case)
○ switch–<n>: where n=1–6
● -v — VLAN settings has following legal values: no arguments imply remove VLAN tag, not compatible
with server–nx (for example "server–4b") notation <vlan_id>=between 1 and 4000, 4021 and 4094,
inclusive <vlan_priority>=between 0 and 7, inclusive.
● -p — Disables IPv4(default) or IPv6 protocol.
● -k — Option has following legal values: no arguments imply autonegotiate <speed>=10, 100
<duplex> =half, full.
NOTE:
● -o, -k, -p: These options can be specified for chassis only
● -6: Sets static IPv6 addresses (with -soption). Enables autoconfig for IPv6 (with-d option)
disables IPv6 (with-p option) can be specified for chassis or servers.
● -v: When performing on a switch, release and renew any DHCP lease on that port for changes to
take effect.
Example
● Configuration of Speed= 100 Mbps and duplex= full duplex.
racadm setniccfg -k 100 full
● Configuration of Speed and Duplex to Autonegotiate.
racadm setniccfg -k
● Configuration of VLAN id and priority of a slot or all blades in a sleeve.
racadm setniccfg -i 5 -v 1000 7
● Configuration of CMC to a static IPv6 address.
racadm setniccfg -m chassis -s -6 2001:DB8::2 64 2001:DB8::1
● Configuration of server to use stateless autoconfiguration address.
racadm setniccfg -m server-1 -d -6
● Configuration of VLAN id and priority for a switch.
racadm setniccfg -m switch-1 -v 1000 7
● Removal of VLAN configuration from a switch.
racadm setniccfg -m switch-1 -v
RACADM Subcommand Details
83