Reference Guide
Table Of Contents
- Chassis Management Controller Version 5.2 for Dell PowerEdge M1000e RACADM Command Line Reference Guide
- Contents
- Introduction
- RACADM Subcommand Details
- Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands
- racadm ? and ? subcommand
- help and help subcommand
- arp
- chassisaction
- chassislog
- closessn
- clrraclog
- clrsel
- cmcchangeover
- config
- connect
- deploy
- eventfilters
- feature
- featurecard
- fwupdate
- get
- getactiveerrors
- getarraycfg
- getassettag
- getchassisname
- getconfig
- getdcinfo
- getflexaddr
- getfanreqinfo
- getioinfo
- getkvminfo
- getled
- getmacaddress
- getmodinfo
- getniccfg
- getpbinfo
- getpminfo
- getraclog
- getractime
- getredundancymode
- getsel
- getsensorinfo
- getslotname
- getssninfo
- getsvctag
- getsysinfo
- gettracelog
- getversion
- ifconfig
- krbkeytabupload
- netstat
- ping
- ping6
- racdump
- racreset
- racresetcfg
- remoteimage
- set
- serveraction
- setarraycfg
- setassettag
- setchassisname
- setflexaddr
- setled
- setniccfg
- setractime
- setslotname
- setsysinfo
- sshpkauth
- sslcertdownload
- sslcertupload
- sslcertview
- sslcsrgen
- sslresetcfg
- testemail
- testfeature
- testtrap
- traceroute
- traceroute6
- CMC Property Database Group and Object Descriptions
- Displayable Characters
- idRacInfo
- cfgLanNetworking
- cfgRemoteHosts
- cfgUserAdmin
- cfgEmailAlert
- cfgSessionManagement
- cfgSerial
- cfgOobSnmp
- cfgTraps
- cfgRacTuning
- cfgServerInfo
- cfgActiveDirectory
- cfgLDAP
- cfgLDAPRoleGroup
- cfgStandardSchema
- cfgLocation
- cfgChassisPower
- cfgChassisDefaultPowerCapLowerBoundBTU (Read Only)
- cfgChassisDefaultPowerCapLowerBound (Read Only)
- cfgChassisDefaultPowerCapUpperBound (Read Only)
- cfgChassisDefaultPowerCapUpperBoundBTU (Read or Write)
- cfgChassisAllow110VACOperationTimestamp (Read Only)
- cfgChassisMaxPowerConservationModeTimestamp (Read Only)
- cfgChassisACPowerRecoveryDisable
- cfgThermal
- cfgKVMInfo
- cfgLcdInfo
- cfgAlerting
- cfgIPv6LanNetworking
- cfgCurrentLanNetworking (Read Only)
- cfgCurrentIPv6LanNetworking (Read Only)
- cfgNetTuning
- cfgRacSecurity
- cfgQuickDeploy
- cfgActionOnServerInsertion
- cfgSetiDRACRootPasswordOnServerInsertion
- cfgiDRACRootPassword
- cfgEnableiDRACLAN
- cfgEnableiDRACIPv4
- cfgEnableiDRACIPMIOverLAN
- cfgEnableiDRACIPv4DHCP
- cfgStartingiDRACIPv4Address
- cfgiDRACIPv4GateWay
- cfgiDRACIPv4Netmask
- cfgEnableiDRACIPv6
- cfgEnableiDRACIPv6AutoConfig
- cfgiDRACIPv6PrefixLength
- cfgiDRACIPv6Gateway
- cfgReservedIPAddressNumbers
- cfgUseCMCDNSSettings
<module> <LED state>
server-10 Blinking
● racadm getled -m chassis
<module> <LED state>
server-10 Not blinking
● racadm getled -m server-1
<module> <LED state>
server-1 ON
● racadm getled -m server-9
<module> <LED state>
server-9 Extension(1)
getmacaddress
Description
Displays the MAC/WWN addresses and fabric ID decoder for all modules or for a specified module.
The decoder values indicate the protocols of the netowrk cards:
● 0 — Unsupported
● 1 — ISCSI
● 2 — FCoE-FIP
● 3 — iSCSI/FCoE-FIP
To use this subcommand, you must have the CMC Login User privilege.
Synopsis
● racadm getmacaddress
●
racadm getmacaddress -m chassis
● racadm getmacaddress -m switch-<n>
●
racadm getmacaddress [-m <module> [-x]] [-t iscsi]
● racadm getmacaddress [-a]
●
racadm getmacaddress -c IO-Identity
●
racadm getmacaddress -c Flexaddress
●
racadm getmacaddress -c Factory
●
racadm getmacaddress -c all
Input
● -m <module> — Specifies the module whose MAC address you want to view.
<module> may be one of the following:
server-<n>, where n=1–16
server-<nx>, where n=1–8; x=a,b,c,d (lower case)
switch-<n>, where n=1–6
● -t — Displays the iSCSI MAC addresses for all servers or the specified server if used with -m option.
● -x — Displays the extra MACs (Ethernet or iSCSI) for servers with additional LOM MACs and must
be used with -m option.
48 RACADM Subcommand Details