Reference Guide
Table Of Contents
- Chassis Management Controller Version 5.2 for Dell PowerEdge M1000e RACADM Command Line Reference Guide
- Contents
- Introduction
- RACADM Subcommand Details
- Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands
- racadm ? and ? subcommand
- help and help subcommand
- arp
- chassisaction
- chassislog
- closessn
- clrraclog
- clrsel
- cmcchangeover
- config
- connect
- deploy
- eventfilters
- feature
- featurecard
- fwupdate
- get
- getactiveerrors
- getarraycfg
- getassettag
- getchassisname
- getconfig
- getdcinfo
- getflexaddr
- getfanreqinfo
- getioinfo
- getkvminfo
- getled
- getmacaddress
- getmodinfo
- getniccfg
- getpbinfo
- getpminfo
- getraclog
- getractime
- getredundancymode
- getsel
- getsensorinfo
- getslotname
- getssninfo
- getsvctag
- getsysinfo
- gettracelog
- getversion
- ifconfig
- krbkeytabupload
- netstat
- ping
- ping6
- racdump
- racreset
- racresetcfg
- remoteimage
- set
- serveraction
- setarraycfg
- setassettag
- setchassisname
- setflexaddr
- setled
- setniccfg
- setractime
- setslotname
- setsysinfo
- sshpkauth
- sslcertdownload
- sslcertupload
- sslcertview
- sslcsrgen
- sslresetcfg
- testemail
- testfeature
- testtrap
- traceroute
- traceroute6
- CMC Property Database Group and Object Descriptions
- Displayable Characters
- idRacInfo
- cfgLanNetworking
- cfgRemoteHosts
- cfgUserAdmin
- cfgEmailAlert
- cfgSessionManagement
- cfgSerial
- cfgOobSnmp
- cfgTraps
- cfgRacTuning
- cfgServerInfo
- cfgActiveDirectory
- cfgLDAP
- cfgLDAPRoleGroup
- cfgStandardSchema
- cfgLocation
- cfgChassisPower
- cfgChassisDefaultPowerCapLowerBoundBTU (Read Only)
- cfgChassisDefaultPowerCapLowerBound (Read Only)
- cfgChassisDefaultPowerCapUpperBound (Read Only)
- cfgChassisDefaultPowerCapUpperBoundBTU (Read or Write)
- cfgChassisAllow110VACOperationTimestamp (Read Only)
- cfgChassisMaxPowerConservationModeTimestamp (Read Only)
- cfgChassisACPowerRecoveryDisable
- cfgThermal
- cfgKVMInfo
- cfgLcdInfo
- cfgAlerting
- cfgIPv6LanNetworking
- cfgCurrentLanNetworking (Read Only)
- cfgCurrentIPv6LanNetworking (Read Only)
- cfgNetTuning
- cfgRacSecurity
- cfgQuickDeploy
- cfgActionOnServerInsertion
- cfgSetiDRACRootPasswordOnServerInsertion
- cfgiDRACRootPassword
- cfgEnableiDRACLAN
- cfgEnableiDRACIPv4
- cfgEnableiDRACIPMIOverLAN
- cfgEnableiDRACIPv4DHCP
- cfgStartingiDRACIPv4Address
- cfgiDRACIPv4GateWay
- cfgiDRACIPv4Netmask
- cfgEnableiDRACIPv6
- cfgEnableiDRACIPv6AutoConfig
- cfgiDRACIPv6PrefixLength
- cfgiDRACIPv6Gateway
- cfgReservedIPAddressNumbers
- cfgUseCMCDNSSettings
NOTE: The fabric type may be any supported I/O fabric type, such as Ethernet, Fibre Channel, and
InfiniBand.
Synopsis
● racadm getioinfo [-m <module>] [-s]
●
racadm getioinfo -o
● racadm getioinfo -m switch-<n> -o
Input
● -m <module> — Specifies the module or device.<module> must be switch — <n>, where n = 1–6
● -s — Displays stack information.
● -o — Displays IOA Flex module information. The possible values for the flex module type are:
○ 0 — 4x10G Base-T FlexIO Module
○ 1 — 4x10G SFP+ FlexIO Module
○ 2 — 2x40G QSFP+ FlexIO Module
○ 3 — 4xFC FlexIO Module
○ 4 — No flex module installed
○ >4 — Invalid
Example
● racadm getioinfo
<IO
>
<Name> <Type> <Presenc
e>
<POST> <Power
>
<Role
>
<SecureMod
e>
<Mode
>
swi
tch
-1
MXL
10/
40GbE
10
GbE KR
Present OK ON Maste
r No
Full
Switc
h
swi
tch
-2
PowerE
dge M
I/O
Aggreg
ator
10
GbE KR
Present OK ON Stand
alone
No
Stand
alone
swi
tch
-3
Brocad
e
M6505
Fibre
Channe
l 16
Present OK ON Maste
r No
Stand
alone
swi
tch
-4
Brocad
e
M6505
Fibre
Channe
l 16
Present OK ON Maste
r No
Stand
alone
swi
tch
-5
PowerE
dge M
I/O
Aggreg
ator
10
GbE KR
Present OK ON Stand
alone
No
Stand
alone
swi
tch
-6
MXL
10/
40GbE
10
GbE KR
Present OK ON Maste
r No
Full
Switc
h
● racadm getioinfo -s
RACADM Subcommand Details