Reference Guide

Table Of Contents
getdcinfo
Description Displays general I/O module and daughter card configuration information. Only the CMC controls daughter
cards.
To run this subcommand, you must have the CMC Login User privilege.
NOTE: Fabric verification for server DCs is performed only when the chassis is turned on. When the
chassis is on standby power, iDRACs on the server modules remain turned off and thus are unable to
report the server's DC fabric type. The DC fabric type may not be reported in the CMC user interface
until iDRAC on the server is turned on.
Synopsis
racadm getdcinfo
racadm getdcinfo [-n]
Input -n Displays the model names for the daughter cards in servers.
Example
The example output below is for a system with multi-slot servers:
racadm getdcinfo
Group A I/O Type : Gigabit Ethernet
Group B I/O Type : Gigabit Ethernet
Group C I/O Type : 10 GbE XAUI
<
IO#>
<Type> <State> <Role>
switch-1 Gigabit Ethernet OK Master
switch-2 None N/A N/A
switch-3 Gigabit Ethernet OK Master
switch-4 None N/A N/A
switch-5 Gigabit Ethernet OK Member
switch-6 None N/A N/A
<Server#> <Presence> <DC1 Type> <DC1 State> <DC2 Type> <DC2 State>
server-1 Present None N/A None N/A
server-2 Not Present None N/A None N/A
38 RACADM Subcommand Details