Reference Guide
Table Of Contents
- Chassis Management Controller Version 5.2 for Dell PowerEdge M1000e RACADM Command Line Reference Guide
- Contents
- Introduction
- RACADM Subcommand Details
- Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands
- racadm ? and ? subcommand
- help and help subcommand
- arp
- chassisaction
- chassislog
- closessn
- clrraclog
- clrsel
- cmcchangeover
- config
- connect
- deploy
- eventfilters
- feature
- featurecard
- fwupdate
- get
- getactiveerrors
- getarraycfg
- getassettag
- getchassisname
- getconfig
- getdcinfo
- getflexaddr
- getfanreqinfo
- getioinfo
- getkvminfo
- getled
- getmacaddress
- getmodinfo
- getniccfg
- getpbinfo
- getpminfo
- getraclog
- getractime
- getredundancymode
- getsel
- getsensorinfo
- getslotname
- getssninfo
- getsvctag
- getsysinfo
- gettracelog
- getversion
- ifconfig
- krbkeytabupload
- netstat
- ping
- ping6
- racdump
- racreset
- racresetcfg
- remoteimage
- set
- serveraction
- setarraycfg
- setassettag
- setchassisname
- setflexaddr
- setled
- setniccfg
- setractime
- setslotname
- setsysinfo
- sshpkauth
- sslcertdownload
- sslcertupload
- sslcertview
- sslcsrgen
- sslresetcfg
- testemail
- testfeature
- testtrap
- traceroute
- traceroute6
- CMC Property Database Group and Object Descriptions
- Displayable Characters
- idRacInfo
- cfgLanNetworking
- cfgRemoteHosts
- cfgUserAdmin
- cfgEmailAlert
- cfgSessionManagement
- cfgSerial
- cfgOobSnmp
- cfgTraps
- cfgRacTuning
- cfgServerInfo
- cfgActiveDirectory
- cfgLDAP
- cfgLDAPRoleGroup
- cfgStandardSchema
- cfgLocation
- cfgChassisPower
- cfgChassisDefaultPowerCapLowerBoundBTU (Read Only)
- cfgChassisDefaultPowerCapLowerBound (Read Only)
- cfgChassisDefaultPowerCapUpperBound (Read Only)
- cfgChassisDefaultPowerCapUpperBoundBTU (Read or Write)
- cfgChassisAllow110VACOperationTimestamp (Read Only)
- cfgChassisMaxPowerConservationModeTimestamp (Read Only)
- cfgChassisACPowerRecoveryDisable
- cfgThermal
- cfgKVMInfo
- cfgLcdInfo
- cfgAlerting
- cfgIPv6LanNetworking
- cfgCurrentLanNetworking (Read Only)
- cfgCurrentIPv6LanNetworking (Read Only)
- cfgNetTuning
- cfgRacSecurity
- cfgQuickDeploy
- cfgActionOnServerInsertion
- cfgSetiDRACRootPasswordOnServerInsertion
- cfgiDRACRootPassword
- cfgEnableiDRACLAN
- cfgEnableiDRACIPv4
- cfgEnableiDRACIPMIOverLAN
- cfgEnableiDRACIPv4DHCP
- cfgStartingiDRACIPv4Address
- cfgiDRACIPv4GateWay
- cfgiDRACIPv4Netmask
- cfgEnableiDRACIPv6
- cfgEnableiDRACIPv6AutoConfig
- cfgiDRACIPv6PrefixLength
- cfgiDRACIPv6Gateway
- cfgReservedIPAddressNumbers
- cfgUseCMCDNSSettings
● The error message displayed for invalid syntax.
racadm getactiveerrors –z cmc-1
ERROR: The syntax of the command specified is not correct.
● The error message displayed for invalid parameter.
racadm getactiveerrors –m server-80
ERROR: The syntax of the command specified is not correct.
● To display entire information log.
racadm getactiveerrors -s info
Module ID = 1
Severity = Critical
Message = A fabric mismatch deteceted for mezzanine card B1.
Module ID = ps-1
Severity = Critical
Message = The power input for power supply 1 is lost.
Module ID = ps-3
Severity = Critical
Message = The power input for power supply 3 is lost.
Module ID = cmc-1
Severity = NonCritical
Message = A firmware or software incompatibilty detected between system
BIOS in slot 4 and CMC.
● Display specific module log:
racadm getactiveerrors -m server-1
getarraycfg
Description
To display the storage array properties and configuration status, run this command.
Synopsis
getarraycfg -m <module> [-s]
Input
● -m — The valid value for —m <module> is server–<n>, where n = 1 to 7 and 9 to 15.
● -s — Query for current storage configuration process status.
Output Array configured properties for:
● Member Name
● Member IP
● Group Name
● Group IP
● Fabric Selection
<module> configuration completed successfully.
Example
● Get the configured storage array properties from server–3.
racadm getarraycfg -m server-3
● Query for current storage configuration process status on server–3.
racadm getarraycfg -m server-3 -s
34 RACADM Subcommand Details