Reference Guide
Table Of Contents
- Chassis Management Controller Version 5.2 for Dell PowerEdge M1000e RACADM Command Line Reference Guide
- Contents
- Introduction
- RACADM Subcommand Details
- Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands
- racadm ? and ? subcommand
- help and help subcommand
- arp
- chassisaction
- chassislog
- closessn
- clrraclog
- clrsel
- cmcchangeover
- config
- connect
- deploy
- eventfilters
- feature
- featurecard
- fwupdate
- get
- getactiveerrors
- getarraycfg
- getassettag
- getchassisname
- getconfig
- getdcinfo
- getflexaddr
- getfanreqinfo
- getioinfo
- getkvminfo
- getled
- getmacaddress
- getmodinfo
- getniccfg
- getpbinfo
- getpminfo
- getraclog
- getractime
- getredundancymode
- getsel
- getsensorinfo
- getslotname
- getssninfo
- getsvctag
- getsysinfo
- gettracelog
- getversion
- ifconfig
- krbkeytabupload
- netstat
- ping
- ping6
- racdump
- racreset
- racresetcfg
- remoteimage
- set
- serveraction
- setarraycfg
- setassettag
- setchassisname
- setflexaddr
- setled
- setniccfg
- setractime
- setslotname
- setsysinfo
- sshpkauth
- sslcertdownload
- sslcertupload
- sslcertview
- sslcsrgen
- sslresetcfg
- testemail
- testfeature
- testtrap
- traceroute
- traceroute6
- CMC Property Database Group and Object Descriptions
- Displayable Characters
- idRacInfo
- cfgLanNetworking
- cfgRemoteHosts
- cfgUserAdmin
- cfgEmailAlert
- cfgSessionManagement
- cfgSerial
- cfgOobSnmp
- cfgTraps
- cfgRacTuning
- cfgServerInfo
- cfgActiveDirectory
- cfgLDAP
- cfgLDAPRoleGroup
- cfgStandardSchema
- cfgLocation
- cfgChassisPower
- cfgChassisDefaultPowerCapLowerBoundBTU (Read Only)
- cfgChassisDefaultPowerCapLowerBound (Read Only)
- cfgChassisDefaultPowerCapUpperBound (Read Only)
- cfgChassisDefaultPowerCapUpperBoundBTU (Read or Write)
- cfgChassisAllow110VACOperationTimestamp (Read Only)
- cfgChassisMaxPowerConservationModeTimestamp (Read Only)
- cfgChassisACPowerRecoveryDisable
- cfgThermal
- cfgKVMInfo
- cfgLcdInfo
- cfgAlerting
- cfgIPv6LanNetworking
- cfgCurrentLanNetworking (Read Only)
- cfgCurrentIPv6LanNetworking (Read Only)
- cfgNetTuning
- cfgRacSecurity
- cfgQuickDeploy
- cfgActionOnServerInsertion
- cfgSetiDRACRootPasswordOnServerInsertion
- cfgiDRACRootPassword
- cfgEnableiDRACLAN
- cfgEnableiDRACIPv4
- cfgEnableiDRACIPMIOverLAN
- cfgEnableiDRACIPv4DHCP
- cfgStartingiDRACIPv4Address
- cfgiDRACIPv4GateWay
- cfgiDRACIPv4Netmask
- cfgEnableiDRACIPv6
- cfgEnableiDRACIPv6AutoConfig
- cfgiDRACIPv6PrefixLength
- cfgiDRACIPv6Gateway
- cfgReservedIPAddressNumbers
- cfgUseCMCDNSSettings
NOTE: When the FlexAddress and FlexAddressPlus feature are active, deactivating one of them results
in deactivation of the other feature also.
-1
—Configures extended storage feature for standalone use.
-2
—Configures extended storage feature for redundant use.
-r
—Reformats damaged or unformatted extended storage media.
CAUTION: Using the -r switch deactivates the extended storage feature, if active; reformats
the SD card in the active CMC card slot; and may Restart the active CMC.
-c
— <featurename> — must be one of the following:
●
flexAddress
●
flexAddressPlus
●
ExtendedStorage (with -d, or -r)
NOTE: The —a option is not supported for CMC 5.0.
Example
● Display the current status of all chassis features:
racadm feature -s
● Deactivate the FlexAddressPlus feature on the chassis:
racadm feature -d -c FlexAddressPlus
featurecard
Description
Verifies proper SD card installation and displays the SD card status.
To use this subcommand, you must have the Chassis Configuration Administrator privilege.
Synopsis
racadm featurecard -s
Input
-s — Lists active SD card features and SD card status.
Output
● No feature card inserted — Action: To verify that the SD card was properly inserted, check
the CMC. In a redundant CMC configuration, make sure the CMC with the SD feature card installed is
the active CMC and not the standby CMC.
● The feature card inserted is valid and contains the following feature(s)
FlexAddress: The feature card is bound to this chassis — Action: No action
required.
● No features active on the chassis — Action: Install the SD card into the CMC.
● The feature card inserted is valid and contains the following feature(s)
FlexAddress: The feature card is bound to another chassis, svctag =
ABC1234, SD card SN = 01122334455
Action: Remove the SD card; locate and install the SD card for the current chassis.
RACADM Subcommand Details 27