Reference Guide
Table Of Contents
- Chassis Management Controller Version 5.2 for Dell PowerEdge M1000e RACADM Command Line Reference Guide
- Contents
- Introduction
- RACADM Subcommand Details
- Guidelines to Quote Strings Containing Special Characters When Using RACADM Commands
- racadm ? and ? subcommand
- help and help subcommand
- arp
- chassisaction
- chassislog
- closessn
- clrraclog
- clrsel
- cmcchangeover
- config
- connect
- deploy
- eventfilters
- feature
- featurecard
- fwupdate
- get
- getactiveerrors
- getarraycfg
- getassettag
- getchassisname
- getconfig
- getdcinfo
- getflexaddr
- getfanreqinfo
- getioinfo
- getkvminfo
- getled
- getmacaddress
- getmodinfo
- getniccfg
- getpbinfo
- getpminfo
- getraclog
- getractime
- getredundancymode
- getsel
- getsensorinfo
- getslotname
- getssninfo
- getsvctag
- getsysinfo
- gettracelog
- getversion
- ifconfig
- krbkeytabupload
- netstat
- ping
- ping6
- racdump
- racreset
- racresetcfg
- remoteimage
- set
- serveraction
- setarraycfg
- setassettag
- setchassisname
- setflexaddr
- setled
- setniccfg
- setractime
- setslotname
- setsysinfo
- sshpkauth
- sslcertdownload
- sslcertupload
- sslcertview
- sslcsrgen
- sslresetcfg
- testemail
- testfeature
- testtrap
- traceroute
- traceroute6
- CMC Property Database Group and Object Descriptions
- Displayable Characters
- idRacInfo
- cfgLanNetworking
- cfgRemoteHosts
- cfgUserAdmin
- cfgEmailAlert
- cfgSessionManagement
- cfgSerial
- cfgOobSnmp
- cfgTraps
- cfgRacTuning
- cfgServerInfo
- cfgActiveDirectory
- cfgLDAP
- cfgLDAPRoleGroup
- cfgStandardSchema
- cfgLocation
- cfgChassisPower
- cfgChassisDefaultPowerCapLowerBoundBTU (Read Only)
- cfgChassisDefaultPowerCapLowerBound (Read Only)
- cfgChassisDefaultPowerCapUpperBound (Read Only)
- cfgChassisDefaultPowerCapUpperBoundBTU (Read or Write)
- cfgChassisAllow110VACOperationTimestamp (Read Only)
- cfgChassisMaxPowerConservationModeTimestamp (Read Only)
- cfgChassisACPowerRecoveryDisable
- cfgThermal
- cfgKVMInfo
- cfgLcdInfo
- cfgAlerting
- cfgIPv6LanNetworking
- cfgCurrentLanNetworking (Read Only)
- cfgCurrentIPv6LanNetworking (Read Only)
- cfgNetTuning
- cfgRacSecurity
- cfgQuickDeploy
- cfgActionOnServerInsertion
- cfgSetiDRACRootPasswordOnServerInsertion
- cfgiDRACRootPassword
- cfgEnableiDRACLAN
- cfgEnableiDRACIPv4
- cfgEnableiDRACIPMIOverLAN
- cfgEnableiDRACIPv4DHCP
- cfgStartingiDRACIPv4Address
- cfgiDRACIPv4GateWay
- cfgiDRACIPv4Netmask
- cfgEnableiDRACIPv6
- cfgEnableiDRACIPv6AutoConfig
- cfgiDRACIPv6PrefixLength
- cfgiDRACIPv6Gateway
- cfgReservedIPAddressNumbers
- cfgUseCMCDNSSettings
The mycmc.cfg file may be created from the getconfig command. This file may also be edited
manually using the parsing rules.
NOTE: The mycmc.cfg file does not contain passwords. To include passwords in the file, you must
enter them manually.
● To configure the single property of a group:
racadm config -g cfgSerial -o cfgSerialBaudRate
● To modify a user password:
racadm config -g cfgUserAdmin -o cfgUserAdminPassword -i 3 <newpassword>
● To configure the single property of a group for a particular server:
racadm config -g cfgSessionManagement -o cfgSsnMgtWebServerTimeout
newvalue -m server-n
● To configure the remote Syslog property for a particular server:
racadm config -g cfgRemoteHosts -o cfgRhostsSyslogEnable 1 -m server-n
● To configure the remote Syslog property for all servers:
racadm config -g cfgRemoteHosts -o cfgRhostsSyslogEnable 1 -m server-all
● Configures the Enhanced Cooling Mode property for fans.
racadm config –g cfgThermal –o cfgThermalEnhancedCoolingMode 1
connect
Description
Connects to the switch or blade server serial console.
NOTE: This subcommand is only supported on the firmware interface(s).
Synopsis
● racadm connect [-b] —m <module>
Input
-b — Connects to the switch or console using the binary mode. -b is an optional; a server or a switch
must be present.
NOTE: If you use the -b option, reset the CMC to end the connect operation.
-m <module> — Must be one of the following values:
● server –<n> — where n=1–16
● server –<nx> — where n=1–8; x = a, b, c, d (lower case)
● switch –<n> — where n = 1 to 6 or <a1 | a2 | b1 | b2 | c1 | c2>
Example
● Connect to I/O Module 1 serial console:
racadm connect -m switch-1
● Connect to server 1 serial console:
racadm connect -m server-1
deploy
Table 3. deploy
Description Deploys blade server or IOM by specifying the required properties.
22 RACADM Subcommand Details