The mycmc.cfg file may be created from the getconfig command. This file may also be edited
manually using the parsing rules.
NOTE: The mycmc.cfg file does not contain passwords. To include passwords in the file, you must
enter them manually.
To configure the single property of a group:
racadm config -g cfgSerial -o cfgSerialBaudRate
To modify a user password:
racadm config -g cfgUserAdmin -o cfgUserAdminPassword -i 3 <newpassword>
To configure the single property of a group for a particular server:
racadm config -g cfgSessionManagement -o cfgSsnMgtWebServerTimeout
newvalue -m server-n
To configure the remote Syslog property for a particular server:
racadm config -g cfgRemoteHosts -o cfgRhostsSyslogEnable 1 -m server-n
To configure the remote Syslog property for all servers:
racadm config -g cfgRemoteHosts -o cfgRhostsSyslogEnable 1 -m server-all
Configures the Enhanced Cooling Mode property for fans.
racadm config g cfgThermal o cfgThermalEnhancedCoolingMode 1
connect
Description
Connects to the switch or blade server serial console.
NOTE: This subcommand is only supported on the firmware interface(s).
Synopsis
racadm connect [-b] m <module>
Input
-b Connects to the switch or console using the binary mode. -b is an optional; a server or a switch
must be present.
NOTE: If you use the -b option, reset the CMC to end the connect operation.
-m <module> Must be one of the following values:
server <n> where n=116
server <nx> where n=18; x = a, b, c, d (lower case)
switch <n> where n = 1 to 6 or <a1 | a2 | b1 | b2 | c1 | c2>
Example
Connect to I/O Module 1 serial console:
racadm connect -m switch-1
Connect to server 1 serial console:
racadm connect -m server-1
deploy
Table 3. deploy
Description Deploys blade server or IOM by specifying the required properties.