Reference Guide

Table Of Contents
5 (critical)
6 (nonrecoverable)
Default
None
cfgChassisRedundantState (Read or Write)
Description
Enables or disables power redundancy for the chassis.
Legal Values
0 No Redundancy
1 Grid Redundancy
2 PSU Redundancy
Default 0
cfgChassisDefaultPowerCapLowerBoundBTU (Read Only)
Description
Displays the default power cap lower bound value using British Thermal Unit (BTU).
Legal Values
None
Default
9263 BTU/h
cfgChassisDefaultPowerCapLowerBound (Read Only)
Description
Displays the default power cap lower bound value.
Legal Values
None
Default
2715 W
cfgChassisDefaultPowerCapUpperBound (Read Only)
Description
Displays the default power cap upper bound value.
Legal Values
None
Default
16685 W
cfgChassisDefaultPowerCapUpperBoundBTU (Read or Write)
Description
Displays the default power cap upper bound value using British Thermal Unit (BTU).
Legal Values
None
Default
56931 BTU/h
CMC Property Database Group and Object Descriptions 137