Users Guide

IP6 Global Address: <address> Only displays if IPv6 is enabled only on an active
CMC.
MAC: <address> Displays the CMC's MAC address.
Table 54. Chassis or Enclosure Status
Item Description
User Define Name Example: “Dell Rack System”. You can set this
option through the CMC Command Line Interface
(CLI) or Web interface.
Error Messages If there are no errors then the message “No Errors”
is displayed, else error messages are listed. Critical
errors are listed first, followed by warnings.
Model Number Example "PowerEdgeM1000e".
Power Consumption Current power consumption in watts.
Peak Power Peak power consumed in watts.
Minimum Power Minimum power consumed in watts.
Ambient Temperature Current ambient temperature in degrees Celsius.
Service Tag The factory-assigned service tag.
CMC redundancy mode Non-Redundant or Redundant.
PSU redundancy mode Non-Redundant, AC Redundant, or DC Redundant.
Table 55. Fan Status
Item Description
Name/Location Example: Fan1, Fan2, and so on.
Error Messages If no error then "No Errors" is shown; otherwise
error messages are listed, critical errors first, then
warnings.
RPM Current fan speed in RPM.
Table 56. PSU Status
Item Description
Name/Location Example: PSU1, PSU2, and so on.
Error Messages If there are no errors then the message “No Errors”
is displayed, else error messages are listed. Critical
errors are listed first, followed by warnings.
Status Offline, Online, or Standby.
Maximum Wattage Maximum Wattage that PSU can supply to the
system.
282