Users Guide
Configuring Enhanced Cooling Mode for Fans Using RACADM
To enable and configure the Enhanced Cooling Mode for fans, use the following RACADM object under
the cfgThermal group:
cfgThermalEnhancedCoolingMode
For example, to enable the ECM mode, use:
racadm config –g cfgThermal –o cfgThermalEnhancedCoolingMode 1
In case of errors, an error message is displayed. The default value of Enhanced Cooling Mode option is
disabled (0). This value is set to disabled (0) when racresetcfg command is issued.
To view the current ECM mode, use:
racadm getconfig –g cfgThermal
To view the current state of ECM mode, use:
racadm getfanreqinfo
[Enhanced Cooling Mode]
Enhanced Cooling Mode(ECM) Status = Disabled
For more information, see the Chassis Management Controller for Dell PowerEdge M1000e RACADM
Command Line Reference Guide available at dell.com/support/manuals.
113