Reference Guide
Input -i <index> — Specifies the index of the email alert to test.
Output
Success: Test e-mail sent successfully
Failure: Unable to send test e-mail
Example • Send a test email to the destination email address configured for index 1
racadm testemail -i 1
testfeature
Description Tests CMC feature x.
Synopsis
• racadm testfeature -f AD -u <user_at_domain> -p <password> [-d
<debug_level>]
• racadm testfeature -f ADKRB -u <user_at_domain> -p <password> [-
d <debug_level>]
• racadm testfeature -f LDAP -u <user> -p <password> [-d
<debug_level>]
Input
• -f <feature> — options are:
– AD — Test AD using simple authentication
– ADKRB — Test AD using Kerberos authentication
– LDAP — Test Generic LDAP
• -u <user>— On the basis of a feature, <user> is user or user_at_domain.
• -p <password> — Password for the user.
• -d <debug_level> — The following bitmask:
– 0x00 — quiet
– 0x01 — verbose
– 0x02 — debug
– 0x04 — info
– 0x08 — warning
– 0x10 — errors
– 0x20 — fatal
– 0x40 — checks
– 0xff — all debug information
– 0xd0 — default debug level for AD and ADKRB.
– 0xf0 and 0xf2 — default debug level for LDAP.
NOTE: -d option is only supported on the firmware interface or firmware
interfaces.
Example
• To test AD.
racadm testfeature -f AD -u joe@dell.com -p dell123
• To test ADKRB:.
racadm testfeature -f ADKRB -u joe@dell.com
89