Reference Guide

setled
Description Sets the state (blinking or not blinking) of the LED on the specified module.
To blink or unblink the chassis, I/O modules or the CMC, you must have the Debug
Administrator privilege. To enable the servers to blink or unblink, you must have the
Server Administrator or the Debug Administrator privilege.
Synopsis
racadm setled -m <module> -l <ledState>
Input
-m <module> — Specifies the module whose LED you want to configure.
<module> can be one of the following:
server–<n>, where n=1–16
server–<nx>, where n=1–8; x = a, b, c, d (lower case)
switch–<n>, where n=1–6
cmc-active
chassis
-l <ledState> — Specifies the LED state. The values are:
0 — No Blinking
1 — Blinking
Example
racadm setled -m chassis -l 1
Sets LED state on Chassis to Blink
racadm setled -m server-1 -1 1
LED state was set successfully.
racadm setled -m server-9 -1 1
ERROR: Server in slot 9 is an extension of the server in slot 1.
NOTE: The setled command generates an error when run on the extension
slot of a multi-slot server.
setniccfg
Description Sets the CMC IP address for static and DHCP modes.
To run this subcommand, you must have the Configure Chassis Administrator privilege.
NOTE: The command helps to modify network configuration properties.
NOTE: The terms NIC and Ethernet management port may be used
interchangeably.
Synopsis
racadm setniccfg [-m <module>] -d [-6]
racadm setniccfg [-m <module>] -s <ipAddress> <netmask>
<gateway>
racadm setniccfg [-m <module>] -s -6 <ipv6Address> <prefixlen>
<gateway>
79